83123014 Crouzet USA, 83123014 Datasheet - Page 74

no-image

83123014

Manufacturer Part Number
83123014
Description
SLDSW 5A NOCBL FLTPBPLSENVBT
Manufacturer
Crouzet USA
Datasheet

Specifications of 83123014

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Hinged Limit Switches Series 83 893 IP 67
3/66
General characteristics
Environment
Conforming
to standards
Certifications
Protective treatment
Temperature
Vibration resistance
Shock resistance
Degree of protection
Cable entry
Electrical characteristics
Assigned working characteristics
Assigned insulation voltage
Assigned impulse voltage
Thermal rating
Electric shock protection
Resistance between terminals
Short-circuit protection
Connection
Electrical life
Minimum actuation speed
Door hinge safety switches for monitoring the cover,
or rotating housing on small machinery
Plastic bodies and heads
Stainless steel lever and fixing accessories
Heads have 4 possible positions
Positive opening contacts
Standard products
Products
Machine
assemblies
Use
Stored
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
AC 15 A 300 Ue = 240 V, Ie = 3A
DC 13 Q 300 Ue = 250 V, Ie = 0.27 A
Ui = 500 V according to IEC 947-5-1
Ui = 300 V according to UL 508,
CSA C22-2 no. 14
Uimp = 6 KV according to
IEC 947-5-1
Ithe = 10 A according to IEC 947-5-1
Class 2 according to IEC 536
≤ 30 m Ω
Cartridge fuse 10 A gG (gl)
Screw clamp terminals
Clamping capacity min. 1 x 0.5 mm
max. 1.5 mm
According to IEC 947-5-1 appendix C
0.01 m/s
IEC 947-5-1, EN 60 947-5-1,
UL 508, CSA C22-2 no. 14,
JIS C4520 (See P. 2/2 and 2/3)
IEC 204-1, EN 60 204-1,
EN 1088, EN 292
UL, CSA
In normal operation: "TC" and "TH"
-25°C, +70°C
-40°C, +70°C
25 gn (10…500 Hz)
according to IEC 68-2-6
11 gn (duration 11 ms)
according to IEC 28-2-27
IP 67 according to IEC 529 and
IEC 947-5-1
One threaded entry for cable gland
11
Example: Safety limit switch 83 893 302
according to IEC 954-5-4
1
Products and specifications subject to change without notice.
2
Part number
with or without ferrule
To order, specify:
2
,
0
Part numbers
Position of lever
Type of contact
NC+NO
Additional characteristics
Tripping angle
Minimum actuation torque
Minimum positive opening torque
Mechanical life
Pg11 cable entry according to NFC 68 300
Weight
Operation
Lever movement
83 893 301 / 303
Operating diagrams
83 893 301 / 303
Operation of contacts
closed
open
180°
2-pole contact NC+NO break before make, slow action
21-22
13-14
or
-90°
83 893 302
83 893 302
-5°
-7° +7°
0
+5°
+90°
21-22
13-14
-270°
83 893 401
83 893 401
-5°
-7° +7°
0
+5°
+270°
21-22
13-14

Related parts for 83123014