Specifications of A22E-M-02

Circuit
DPST-NC
Switch Function
On-Off
Contact Rating @ Voltage
10A @ 110VAC
Actuator Type
Mushroom Button
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Contact Form
DPST - NC
Contact Rating
10 Amps
Actuator
Round, Medium
Mounting Style
Quick Connect
Terminal Seal
IP65
Illumination
Not Illuminated
Illumination Color
Red
Features
Easy mounting and removal of switch unit
Mounting Angle
Horizontal
Contact Configuration
DPST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
440V
Contact Voltage Dc Nom
380V
Contact Current Max
10A
Actuator Style
Round
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Illumination Type, Color
-
Illumination Voltage (nominal)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
A22EM02

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
A22E-M-02-EMO
Manufacturer:
OMRON
Quantity:
1 000
emergency Stop Switch
(22-dia. or 25-dia.)
• Install in 22-dia. or 25-dia. panel cutout
• Direct opening mechanism to open the circuit when the contact
• Safety lock mechanism prevents operating errors.
• Easy mounting and removal of Switch Blocks using a lever.
• Mount three Switch Units in series to improve wiring efficiency
• Finger protection mechanism on Switch Unit provided as a
• Install using either round, or forked crimp terminals.
• Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models)
• A lock plate is provided as a standard feature to ensure that the
Specifications
certified Standard ratings
• UL, cUL (File No.E41515)
• TÜV (EN60947-5-1) (Low Voltage Directive)
• CCC (GB14048.5)
certified Standards
Note: Only models with NC contacts have a direct opening mechanism.
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Some models have been certified. Certification has been obtained for
the Switch Unit and the Lamp Socket.
certification
body
UL *1
TÜV SÜD
CQC (CCC)
KOSHA *2
Safety interlock Switches
A22e
welds → .
(with non-lighted Switch Units, three Units can be mounted for
multiple contacts).
standard feature.
control box and switch are not easily separated.
6A at 220 VAC, 10 A at 110 VAC
3 A at 220 VAC
3 A at 240 VAC, 1.5 A at 24 VDC
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
Standard
UL 508, CSA C22.2 No.14
EN60947-5-1,
EN60947-5-5
(certified direct opening
mechanism)
GB14048.5
EN60947-5-1
canada
Tel. 1/866/986-6766
file no.
E41515
Consult your
representative for
details.
2003010303070635
2004-220, 2007-27
ratings
contacts (Standard load)
Note:
1. Rated current values are determined according to the testing conditions.
2. Minimum applicable load: 10 mA at 5 VDC
leD indicators without Voltage reduction Unit
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
current
rated
carry
The above ratings were obtained by conducting tests under the following
conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
(A)
10
rated voltage
12 VAC/VDC
24 VAC/VDC
6 VDC
6 VAC
110 VAC
220 VAC
380 VAC
440 VAC
110 VDC
220 VDC
380 VDC
voltage
24 VDC
24 VAC
rated
(V)
(inductive
Ac15
load)
10
---
5
3
2
1
rated current
60 mA
60 mA
30 mA
15 mA
(resistive
Ac12
rated current (A)
load)
10
10
---
6
3
2
(inductive
Dc13
load)
Operating voltage
A22E
1.5
0.5
0.2
0.1
12 VAC/VDC±5%
24 VAC/VDC±5%
---
6 VDC±5%
6 VAC±5%
(resistive
Dc12
load)
0.6
0.2
---
10
2
g11
g

Related parts for A22E-M-02

A22E-M-02 Summary of contents

Page 1

... Ambient humidity: 65±5% (3) Operating frequency: 20 operations/minute 2. Minimum applicable load VDC leD indicators without Voltage reduction Unit rated voltage 6 VDC 6 VAC 12 VAC/VDC 24 VAC/VDC For the Latest Information On the Internet: www.sti.com or www.omron.ca A22E rated current (A) Ac15 Ac12 Dc13 Dc12 (inductive (resistive (inductive (resistive load) ...

Page 2

... Switch dimensions when mounted to a DPSt-nO (or DPSt-nc) one-piece Switch Block 1.8 18.5 0.5 5.9 32 41.2 Note: The operation unit is an example for the A22E-M. 54.7 For the Latest Information Tel. 1/866/986-6766 On the Internet: www.sti.com or www.omron.ca A22e Safety interlock Switches (mm) 60 dia. 34 1.8 0.5 5 ...

Page 3

... SPST-NO/SPST-NC A22E-LP-11 DPST-NC A22E-LP-02 SPST-NC A22E-S-01 * SPST-NO/SPST-NC A22E-S-11 * DPST-NC A22E-S-02 * DPST-NC + SPST-NO A22E-S12 * TPST-NC A22E-S-03 * SPST-NC A22E-M-01 * SPST-NO/SPST-NC A22E-M-11 * DPST-NC A22E-M-02 * DPST-NC + SPST-NO A22E-M-12 * TPST-NC A22E-M-03 * SPST-NC A22E-L-01 * SPST-NO/SPST-NC A22E-L-11 * DPST-NC A22E-L-02 * SPST-NC A22E-SK-01 SPST-NO/SPST-NC A22E-SK-11 DPST-NC A22E-SK-02 SPST-NC A22E-MK-01 SPST-NO/SPST-NC ...

Page 4

... DPST-NC + SPST-NO TPST-NC SPST-NC SPST-NO/SPST-NC DPST-NC DPST-NC + SPST-NO TPST-NC model A22E-M-01B * A22E-M-11B * A22E-M-02B * A22E-M-12B A22E-MP-12B = Highlighted rapid Delivery products are available for shipment today or within fiVe days. A22E-M-24A-02B For the Latest Information Tel. 1/866/986-6766 On the Internet: www.sti.com or www.omron.ca A22e Safety interlock Switches ...

Page 5

... Lighted (without Voltage Reduction Unit) Operation Unit Lamp Incandescent LED Switch (without Voltage Reduction Unit) For the Latest Information On the Internet: www.sti.com or www.omron.ca A22e Safety interlock Switches Lighted (with Voltage Reduction Unit) Operation Unit Lamp LED Switch (with Voltage Reduction Unit) g ...

Page 6

... OmrOn Scientific technOlOgieS, inc. g16 USA canada Tel. 1/888/510-4357 iP65 oil-resistant models Small (30 dia.) medium (40 dia.) A22E-MP --- A22E-M A22E-MK For the Latest Information Tel. 1/866/986-6766 On the Internet: www.sti.com or www.omron.ca A22e Safety interlock Switches large (60 dia.) A22E-LP A22E-L --- ...

Page 7

... Non-lighted Momentary Model A22-01M A22-11M A22-02M Lighted (110 VAC) Lighted (220 VAC) Momentary Model A22L-01M-T1 A22L-11M-T1 A22L-02M-T1 For the Latest Information On the Internet: www.sti.com or www.omron.ca A22e Safety interlock Switches Lighted Momentary Model A22L-01M A22L-11M A22L-02M Momentary Model A22L-01M-T2 A22L-11M-T2 A22L-02M-T2 g17 g ...

Page 8

... Provides SEMI-S2/SEMATECH Application Guide for SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and legend plate for EMERGENCY STOP come as a set. Use with an A22E Emergency Stop Switch. (for emergency stop) * SEMI-S2/SEMATECH Application Guide for SEMI S2-compatible Shroud. (for emergency shutoff) * Use together with an A22E Emergency ...

Related keywords