E2EX3D1S Omron, E2EX3D1S Datasheet - Page 15

no-image

E2EX3D1S

Manufacturer Part Number
E2EX3D1S
Description
Proximity Sensor
Manufacturer
Omron
Datasheet

Specifications of E2EX3D1S

Proximity Sensor Type
Inductive
Proximity Sensor Sensing Distance
3mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
4
Lead Free Status / RoHS Status
Compliant
E2E-X@T1 AC/DC 2-Wire Models
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
*2. Power Supply Voltage Waveform:
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing object
Response
frequency *1
Power supply voltage
(operating voltage range) *2
Leakage current
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Protection circuits
Ambient temperature range Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity range
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
a set distance of half the sensing distance.
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
DC
AC
Load
current
Residual
voltage
Case
Sensing
surface
Clamping
nuts
Toothed
washer
Shielded
Model
Size
3 mm ±10%
0 to 2.4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.)
Iron, 12 × 12 × 1 mm
1 kHz
25 Hz
24 to 240 VDC (20 to 264 VDC)
48 to 240 VAC (40 to 264 VAC)
DC: 1 mA max.
AC: 2 mA max.
5 to 100 mA
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
Operation indicator (red), Setting indicator (green)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.)
Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Operating/Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 1,000 m/s
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Approx. 80 g
Nickel-plated brass
PBT
Nickel-plated brass
Zinc-plated iron
Instruction manual
E2E-X3T1
M12
2
10 times each in X, Y, and Z directions
7 mm ±10%
0 to 5.6 mm
Iron, 18 × 18 × 1 mm
0.5 kHz
Approx. 140 g
E2E-X7T1
Shielded
M18
10 mm ±10%
0 to 8 mm
Iron, 30 × 30 × 1 mm
0.4 kHz
Approx. 190 g
E2E-X10T1
M30
E2E
15

Related parts for E2EX3D1S