Connecting to the RS-232C Port at the Host
Connecting to a CS/CJ-
series Serial
Communications Unit
60
DM32000
DM32001
DM32002
DM32003
m
m+1
m+2
m+3
Allocation DM area (CH)
Allocation DM area (CH)
Port 1
Port 1
Allocation DM Area Settings for CPU Unit
Settings are written from the Programming Device (a Programming Console
or CX-Programmer) directly into the allocation DM area (system setting area)
of the CPU Unit. After the settings are written, they become effective by turn-
ing the power ON, restarting the Unit, restarting the communications port, or
execution of the STUP command.
In the following, the channel numbers of the allocation DM area and the set-
tings are shown.
CS/CJ-series Rack-mounting Unit:
CS1W-SCU21(-V1), CJ1W-SCU21(-V1), CJ1W-SCU41(-V1)
Setting the Front Switches
Set the unit number of the Serial Communications Unit by using the rotary
switch located on the front panel. Set each switch with a flat blade screwdriver
so that the values or symbols in the setting value window agree with the fol-
lowing.
Allocation DM Area Settings for CPU Unit
Settings are written from the Programming Device (a Programming Console
or CX-Programmer) directly into the allocation DM area (system setting area)
of the CPU Unit. After the settings are written, they become effective by turn-
ing the power ON, restarting the Unit, restarting the communications port, or
execution of the STUP command.
In the following, the channel numbers of the allocation DM area and the set-
tings are shown.
m=DM30000+100 × unit # (CH)
RUN
ERC
SD1
RD1
SCU21
m+10
m+11
m+12
m+13
DM32010
DM32011
DM32012
DM32013
UNIT
No.
Port 2
Port 2
1 0
F E
RDY
ERH
SD2
RD2
8000
0000
0007
0000
0000
8000
0000
0007
0000
0000
Writing Value
Set the unit number to 0 through F so
that it will not overlap with the numbers
used in other units.
Writing Value
Host link mode, 2 stop bits, even parity, data
length 7 bits
Communications speed 9600 bps.
Communications speed 19200 bps.
Transmit delay time 0 ms.
No CTS control Unit No.0 for host link
host link mode, 2 stop bits, even parity, data
length 7 bits
Communications speed 9600 bps.
Communications speed 19200 bps.
Transmit delay time 0 ms.
No CTS control Unit No.0 for host link
Settings
Settings
Section 4-1