A3PA-5733-24E Omron, A3PA-5733-24E Datasheet - Page 24

no-image

A3PA-5733-24E

Manufacturer Part Number
A3PA-5733-24E
Description
GREEN/GREEN DISPLAY
Manufacturer
Omron
Series
A3Pr
Datasheet

Specifications of A3PA-5733-24E

Actuator Style
Square Button
Illumination Type
Led
Product Height (mm)
59.3mm
Product Depth (mm)
25mm
Operating Temp Range
-10C to 40C
Mounting Style
Panel
Terminal Type
Quick Connect/Solder
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
A3PA573324E
A3PA573324ENC
Safety Precautions
Refer to Safety Precautions for all Pushbutton Switches.
Do not apply a voltage higher than the maximum
rated operating voltage between the lamp
terminals, as there is a risk that the incandescent
lamp or LED will be damaged, and the Pushbutton
will be ejected.
When replacing the incandescent lamp, first turn
OFF the power supply, and then wait 10 minutes
before performing replacement, as the lamp is still
hot immediately after the power is turned OFF, so
there is a risk of burns.
1. Always make sure that the power is turned OFF before mounting,
2. After wiring the Switch, make sure that there is a suitable isolation
Wiring
Operating Environment
LED (for VDC)
Incandescent Lamp
Character Plate (Character Film)
• Solder quickly and correctly at 350°C max and for 3 s or less.
• Do not use in locations that are subject to dust, oil, or metal filings
• Check the terminal polarity when wiring.
• The rated voltage is shown on the plate on the back of the lighting
• An LED current-limiting resistor is built in, so there is no need to
• Apply 80% of the rated voltage (operating voltage) to the
• If preparing the character plate separately, use a heat-resistant film
Wait for one minute after soldering before exerting any external
force on the solder.
as these may penetrate the interior of the Switch and cause
malfunction.
unit, so be sure to use within the voltage shown.
mount an external resistor.
incandescent lamp to improve life expectancy and incandescence.
with a thickness of 0.1 to 0.3 mm.
removing, or wiring the Switch, or performing maintenance.
Electric shock or fire may occur.
distance.
24.1
24.8
+0
−0.1
+0
−0.3
dia.
Precautions for Correct Use
17.1
5.2
+0
−0.3
+0
−0.3
23. ±
0.1
17.1
dia.
+0
−0.3
Caution
17.1
+0
−0.3
Using Microloads
Others
• Using a standard load switch when a microload circuit is opened or
• If the panel is to be finished (e.g., coated), make sure that the panel
closed may cause contact failure on the contacts. Use the switch
within the operating range. (Refer to the diagram below.) Even
when using microload models within the operating range shown
below, if inrush current occurs when the contact is opened or
closed, it may cause the contact surface to become rough, and so
decrease life expectancy. Therefore, insert a contact protection
circuit where necessary. The minimum applicable load is the N-
level reference value. This value indicates the malfunction
reference level for the reliability level of 60% (λ 60) (conforming to
JIS C5003). The equation, λ 60 = 0.5 x 10
estimated malfunction rate is less than 1/2,000,000 with a reliability
level of 60%.
meets the specified dimensions after the coating.
30
24
12
5
0
0.1
0.15 mA
Invalid
area
1 mA
1
Microload
area
10
26 mA
100 mA 150 mA
100 mA
100
Current (mA)
Standard
load area
1,000
−4
/time indicates that the
A3P
24

Related parts for A3PA-5733-24E