D4B-2A15N Omron, D4B-2A15N Datasheet - Page 15

no-image

D4B-2A15N

Manufacturer Part Number
D4B-2A15N
Description
Safety Limit Switch
Manufacturer
Omron
Datasheet

Specifications of D4B-2A15N

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Wiring
Do not connect the bare lead wires directly to the terminals but be
sure to connect each of them by using an insulation tube and M3.5
round crimp terminals and tighten each terminal screw within the
specified torque range.
The proper lead wire is 20 to 14 AWG (0.5 to 2.5 mm
Make sure that all crimp terminals come into contact with the casing
or cover as shown below, otherwise the cover may not be mounted
properly or the D4B-@N may malfunction.
Ordering Method
The D4B-@N uses a block mounting
method. Switches can be ordered either as
sets or as individual parts. If a set is
ordered, the Switch will be shipped with all
parts assembled.
Note: For Switches with Roller Levers, do
Crimp
terminal
not order just the Head and Lever, or
just the Switch Box and Lever.
Casing
Crimp terminal
dz dia.: 3.7 mm
D dia.: 4.5 mm
B:
L:
F:
l:
7.0 mm
20.2 mm
7.7 mm
9.0 mm
Correct
Correct
Terminal screw
Correct
Incorrect
Crimp terminal
Terminal screw
D dia.
Cover
Casing
Crimp terminal
Incorrect
Incorrect
dz dia.
Terminal screw
Example: D4B-2111N
Crimp terminal
2
Cover
Set model number
) in size.
Conduit Opening
Others
• Make sure that each connector is tightened within the specified
• If the 1/2-14NPT is used, cover the cable and conduit end with
• The Pg13.5 connector must be Nippon Flex’s ABS-08 Pg13.5 or
• Use an OMRON SC-series Connector (sold separately) that is
• Properly attach the provided conduit cap to the unused conduit
• The load for the actuator (roller) of the Switch must be imposed on
• When using a long lever model like the D4B-@@16N or D4B-@@17N,
Switch Box
D4B-2100N
torque range.
The casing may be damaged if the connector is tightened
excessively.
sealing tape in order to ensure IP67.
ABS-12 Pg13.5.
suited to the cable in diameter.
opening and securely tighten the cap screw within the specified
torque when wiring the D4B-@N.
the actuator in the horizontal direction, otherwise the actuator or
the rotating axis may be deformed or damaged.
the Switch may telegraph. To avoid telegraphing, take the following
precautions.
1. Set the lever to operate in one direction.
2. Modify the rear end of the dog to an angle of 15° to 30° as
3. Modify the circuit so as not to detect the wrong operating
shown below or to a secondary-degree curve.
signals.
θ
θ ≥ 30°
Dog
+
+
Individual model numbers
Correct
D4B-0010N
Head
Dog
Incorrect
+
+
θ
*Roller Levers only.
15° ≤ θ ≤ 30°
D4B-0001N
Lever *
D4B-@N
15

Related parts for D4B-2A15N