Specifications of E5AN-HAA2HBMD-500 AC/DC24

No. Of Digits / Alpha
5
Meter Function
Temperature Controller
Meter Range
-200°C To +2300°C
Digit Height
15mm
Supply Voltage Range
24 VAC/VDC
Power Consumption
4W
Rohs Compliant
Yes
Operating Temperature Range
-10°C To +55°C
Specifications
Ratings
Power supply voltage
Operating voltage range
Power consumption
Sensor input
Input impedance
Control method
Control
output
Auxiliary
output
Event
input
Logic
operations
Transfer
outputs
RSP
input
Setting method
Indication method
Bank switching
Other functions
Ambient operating temperature
Ambient operating humidity
Storage temperature
Relay output
Voltage output
(for driving SSR)
Current output
Linear voltage output
Built-in SSR output
Relay output for
position-proportional
control
Number of outputs
Output specifications
Number of outputs
External contact input
specifications
Number of operations
Operations
Output
Work bit
assignment
Number of outputs
Output specifications
Number of inputs
Signal type
Analog input scaling
Accuracy
Input sampling period
No D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
85% to 110% of rated supply voltage
100 to 240 VAC: 12 VA
24 VAC/VDC: 8.5 VA (24 VAC)/5.5 W (24 VDC)
Any of the following can be selected.
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB.)
ON/OFF control or 2-PID control (with auto-tuning)
Output Unit (Install the Output Unit (sold separately).)
75 to 250 VAC, 1 A (resistive load)
Relay output: Open and close: SPST-NO, 250 VAC, 1 A (including in-rush current), electrical life: 100,000 operations min.
Potentiometer input: Must be between 100 Ω and 2.5 kΩ for maximum open position.
2 or 3 max.
Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,
10 mA
2 or 4 (with an E53-AKB)
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
8 max.
• Logic operation: Any of the following four patterns can be selected. The input status may be inverted.
• Delay:
• Output inversion: Possible
One work bit per operation
Any of The following can be assigned to up to eight work bits (logic operation results): Event input operations, auxiliary
outputs, or control outputs.
1 max. (Depends on model. Models with transfer output (F in model number)
Current output: 4 to 20 mA DC, Load: 600 Ω max., Resolution at 4 to 20 mA: Approx. 10,000
1
Current input: 4 to 20 mA (input impedance: 150 Ω ±10%)
Scaling of signal to engineering units (EU)
−19,999 to 30,000 (display: 30,000 max.)
(±0.2% of FS) ±1 digit max.
60 ms
Set digitally using keys on the front panel or by using the RSP input.
11-segment digital display and individual indicators (7-segments displays also possible)
Character height: E5AN-H: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN-H: PV: 11.8 mm, SV: 8.1 mm, MV: 5.8 mm
Content of 3-level display: PV/SV/MV, PV/SV/Bank No., or soak time remain
Number of digits: 5 for PV and SV, 4 for MV
Supported (number of banks: 8)
Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.)
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection, 40%
AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output
ON/OFF counter, extraction of square root, MV change rate limit, PV/SV status display, logic operations, automatic cooling
coefficient adjustment
−10 to 55°C (with no condensation or icing), for 3-year warranty: −10 to 50°C
25% to 85%
−25 to 65°C (with no condensation or icing)
(A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D
(A, B, C, and D are four inputs.)
ON delay or OFF delay for the results of the logic operation given above.
Setting time: 0 to 9999 s or 0 to 9999 min
E5AN-H/E5EN-H