E8CC-B10C Omron, E8CC-B10C Datasheet - Page 6

PRESSURE SENSOR:0to980kPa,wLCD

E8CC-B10C

Manufacturer Part Number
E8CC-B10C
Description
PRESSURE SENSOR:0to980kPa,wLCD
Manufacturer
Omron
Series
E8CCr
Datasheets

Specifications of E8CC-B10C

Pressure Type
Gauge
Operating Pressure
142.14 PSI, 980 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
-10°C ~ 55°C
Package / Case
Module
Mounting Style
DIN Rail
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 10 C
Operating Supply Voltage
15 V, 18 V
Output Voltage
1 V to 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8CCB10C
Setting the Pressure on the E8CC
1. Set the mode selector to SET.
2. Turn the pressure adjuster to the desired pres-
sure.
Indications
(for 30 kPa)
Adjustment
Display
RUN
SET
RUN
SET
RUN
SET
RUN
SET
RUN
SET
Mode
0
http://www.ia.omron.com/
Normal
Normal
Abnormal
pressure
imposition
Abnormal
pressure
setting
Abnormal
pressure
imposition
Abnormal
pressure
setting
Load over-
current
Element
destruction
Operating
−76
status
Displays the imposed pressure within the permissible
range.
Displays the ON-point setting pressure within the per-
missible range
• Positive Pressure:
• Negative Pressure:
• Positive Pressure:
• Negative Pressure:
Indicates that the imposed pressure is higher than the
permissible range.
• Positive Pressure:
• Negative Pressure:
Indicates that the output transistor has excessive load current, in which case, the output of the E8CC
is turned OFF and this display flashes until the condition returns to normal. Check the output wiring
if this display flashes.
Indicates that the Pressure Sensor element is damaged due to the imposition of excessive pressure
or other reasons, in which case, the output of the E8CC is turned OFF. If this display appears, the
E8CC can no longer be used.
Indicates that the imposed pressure is lower than
the permissible range.
Indicates that the imposed pressure is higher than
the permissible range. The E8CC is, however, in
normal output operation in both cases.
Indicates that ON-point setting pressure value is
lower than the permissible range.
Indicates that ON-point setting pressure is higher
than the permissible range. The E8CC is, however,
in normal output operation in both cases.
Indicates that ON-point setting pressure value is
higher than the permissible range.
Indicates that ON-point setting pressure is lower
than the permissible range. The E8CC is, however,
in normal output operation in both cases.
Screwdriver
RUN
SET
Description
3. Set the mode selector to RUN.
The E8CC has, however, normal output in
SET mode. Change in pressure setting is pos-
sible in RUN mode by turning the pressure ad-
juster. Do not turn the pressure adjuster after
the pressure adjuster has been set to the de-
sired pressure.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
E8CC
-A01C
0 to
98 kPa
Positive pressure
Permissible range
E8CC
-B10C
0 to
980 kPa
E8CB/E8CC
pressure
Negative
E8CC
-AN0C
0 to
−101 kPa
0 to
−101 kPa
---
RUN
SET
6