E8CC-B10C Omron, E8CC-B10C Datasheet - Page 9

PRESSURE SENSOR:0to980kPa,wLCD

E8CC-B10C

Manufacturer Part Number
E8CC-B10C
Description
PRESSURE SENSOR:0to980kPa,wLCD
Manufacturer
Omron
Series
E8CCr
Datasheets

Specifications of E8CC-B10C

Pressure Type
Gauge
Operating Pressure
142.14 PSI, 980 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
-10°C ~ 55°C
Package / Case
Module
Mounting Style
DIN Rail
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 10 C
Operating Supply Voltage
15 V, 18 V
Output Voltage
1 V to 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8CCB10C
General Precautions
These products cannot be used in safety devices for
presses or other safety devices used to protect
human life. These products are designed for use in
applications for sensing workpieces and workers
that do not affect safety.
Withstand Pressure
Do not apply a pressure higher than the rated withstand pressure.
Applying a pressure higher than this may cause damage.
Operating Environment
Do not use the products in an environment where there are explosive
or inflammable gases.
Power Supply Voltage
Do not use a voltage that exceeds the power supply voltage range.
Using a voltage that exceeds the range may cause burning.
Load Short-circuiting
Do not short-circuit the load. Doing so may cause explosion or
burning.
Incorrect Wiring
Be sure that the power supply polarity and other wiring is correct.
Incorrect wiring may cause explosion or burning.
Precautions for Safe Use
http://www.ia.omron.com/
WARNING
For precautions on individual products, refer to the Safety Precautions in the individual product information.
Pressure Sensors Technical Guide
• When using a Sensor that supports non-corrosive gas as the
• Do not insert any wire or other object into the pressure port. Doing
• Do not use the Sensor alongside high-voltage lines or power lines.
• Mount the Sensor so that it is not subject to ultrasonic vibration.
• Do not apply a tensile force higher than 30 N to the cable or
• The cable can be extended to a maximum of 10 m. For details, see
applicable fluid, use an air filter to remove moisture and oil from the
gas.
so may damage the pressure elements and cause a malfunction.
connector.
the output impedance section on the previous page.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Precautions for Correct Use
C-1

Related parts for E8CC-B10C