Specifications of MY2-02-AC100/110

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
10mA
Coil Voltage
110VAC
Turn On Voltage (max)
88 VAC
Turn Off Voltage (min)
33 VAC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 220VAC
Control On Voltage (max)
88 VAC
Control Off Voltage (min)
33 VAC
Contact Rating
5 A
Contact Termination
Solder Terminal
Mounting Style
Socket
Power Consumption
0.9 VA to 1.1 VA
Contact Material
Silver
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MY202AC100110
SEV Listings (File No. 99.5 50902.01)
Note: 1. The rated values approved by each of the safety standards (eg., UL, CSA, VDE, and SEV) may be different from the performance char-
PYF-S Installation Notes
■ Tools
A flat-blade screwdriver should be used to mount the cables.
Applicable Screwdriver
● Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)
Examples: FACOM AEF.2.5 × 75E
■ Applicable Wires
Applicable Wire Sizes
0.2 to 1.5 mm
Applicable Wire Type
Solid wires, stranded wires, flexible wires, or wires with ferules can
be used.
(See note 1.)
Conductor diameter d (mm) or length of sides a and b (mm) ≤ 1.9
274
● Flat-blade, Parallel-tip
● Flat-blade, Flared-tip
No. of poles
2
4
*Chamfering the tip of the driver improves insertion when used as an exclusive tool.
2. In the interest of product improvement, specifications are subject to change.
2.5 dia. (3.0 mm max.)
acteristics individually defined in this catalog.
VESSEL No. 9900-(-)2.5 × 75 (No. 9900-(-)3 × 100)
WAGO 210-119
WIHA 260/2.5 × 40
Wires with Ferules
2
<
General-purpose Relay
, AWG24 to AWG16
2.2 ≤ Diameter D (mm) ≤ 3.2 (3.5: see note 2.)
Cannot be used.
Coil ratings
6 to 240 VAC
6 to 125 VDC
(AEF. 3 × 75E)
(260/3 × 50)
MY
Contact ratings
10 A, 250 VAC
10 A, 30 VDC
5 A, 250 VAC
5 A, 30 VDC
Note: 1. If the overall diameter of the wire is less than 2.2 mm, do not
2. If the overall diameter of the wire is over 3.2 mm, it will be
insert the wire past the conductor. Refer to the following di-
agrams.
difficult to use double wiring.
Operations
10 x 10
100 x 10
MY4Z AC; 50 x 10
3
3
3