ASCX05DN-90 Honeywell Sensing and Control, ASCX05DN-90 Datasheet

no-image

ASCX05DN-90

Manufacturer Part Number
ASCX05DN-90
Description
JZ SILICON PRESSURE PRODUCTS
Manufacturer
Honeywell Sensing and Control
Datasheet

Specifications of ASCX05DN-90

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Microstructure Pressure Sensors
Signal Conditioned
0 psi to 1 psi up to 0 psi to 150 psi
FEATURES
• 5 Vdc Supply
• High Level Voltage Output
• Field Interchangeable
• Calibrated and
• Small Form Factor
• Low Power
• Offset Adjust
TYPICAL APPLICATIONS
• Medical Equipment
• Industrial Controls
• Pneumatic Controls
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Sensing and Control
Temperature
Compensated
WARNING
This series is a signal-conditioned version of Honeywell’s proven performer
and industry leading SCX series sensor.
This amplified ASCX device is in a package the same as the SCX but it
offers a high level (4.5 V span) output on a very cost-effective basis. This
family is fully calibrated and temperature compensated over a range of 0 °C
to 70 °C [32 °F to 158 °F] but can be operated from -25 °C to 105 °C [-13 °F
to 221 °F]. These sensors are intended for use with non-corrosive, non-ionic
working fluids such as air and dry gases.
Devices are available to measure absolute, differential and gage pressures
from 1 psi (ASCX01) up to 150 psi (ASCX150). The absolute devices (A)
have an internal vacuum reference and an output voltage proportional to
absolute pressure. Differential devices (D) allow application of pressure to
either side of the sensing diaphragm and can be used for gage or differential
pressure measurements.
The ASCX series devices feature an integrated circuit (IC) sensor element
and laser trimmed thick film ceramic housed in a compact solvent resistant
case. It provides excellent corrosion resistance and isolation to external
packaging stresses. The package has convenient mounting holes and
pressure ports for ease of use with standard plastic tubing for pressure
connection.
All ASCX devices are calibrated for span to within ± 1 % (typically ± 0.2 %)
of FSO. The devices are characterized for operation from a single 5 volt
supply although sensitivity is ratiometric to the supply voltage and any
dc supply from 5 Vdc to 16 Vdc is acceptable.
The ACSX series requires very low quiescent current compared to other
signal conditioned pressure sensors, thus, this series is ideal for battery-
powered applications.
The 100 microseconds response time makes this series an excellent choice
for computer peripherals and pneumatic control applications.
Contact your local honeywell representative, or go to Honeywell’s website at
www.honeywell.com/sensing for additional details.
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do not
• Complete installation, operation, and maintenance information is provided in
Failure to comply with these instructions could result in death or serious
injury.
use this document as a product installation guide.
the instructions supplied with each product.
WARNING
ASCX Series

Related parts for ASCX05DN-90

ASCX05DN-90 Summary of contents

Page 1

Microstructure Pressure Sensors Signal Conditioned 0 psi to 1 psi psi to 150 psi FEATURES • 5 Vdc Supply • High Level Voltage Output • Field Interchangeable • Calibrated and Temperature Compensated • Small Form Factor • ...

Page 2

... Signal Conditioned 0 psi to 1 psi psi to 150 psi PRESSURE RANGE SPECIFICATIONS Operating Proof Model * Pressure Pressure ASCX01DN 0 psid to 1 psid 20 psid ASCX05DN 0 psid to 5 psid 20 psid ASCX15AN 0 psia to 15 psia 30 psia ASCX15DN 0 psid to 15 psid 30 psid ASCX30AN 0 psia to 30 psia 60 psia ...

Page 3

Microstructure Pressure Sensors Signal Conditioned 0 psi to 1 psi psi to 150 psi ASCX PERFORMANCE CHARACTERISTICS Characteristic (5) Offset Models ASCX15/30/100/150xN Models ASCX01/05DN Output @ FS Pressure Combined Pressure Linearity and Hysteresis Temperature Effect on Span ...

Page 4

Microstructure Pressure Sensors Signal Conditioned 0 psi to 1 psi psi to 150 psi PHYSICAL DIMENSIONS for Reference Only (mm/in) WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact ...