H5CX-L8D-N DC12-24/AC24 Omron, H5CX-L8D-N DC12-24/AC24 Datasheet - Page 19

no-image

H5CX-L8D-N DC12-24/AC24

Manufacturer Part Number
H5CX-L8D-N DC12-24/AC24
Description
8-PIN, RLY OUT, Limit, Instant DC12-24/AC24
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-L8D-N DC12-24/AC24

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12 ~ 24VDC, 24VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H5CXL8DNDC1224AC24
Z3000
Settings for Advanced Functions
Settings that cannot be performed with the DIP switch are performed with the operation keys.
See note 1.
3 s min.
Power ON
See note 2.
3 s min.
Time range
Timer mode
Output mode
Output time
Input signal
width
NPN/PNP
input mode
Display color
Key protect
level
(NPN input) (PNP input)
For details on operations in run mode, refer to page 21.
Note 1. If the mode is switched to the function setting mode during operation,
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the
DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set
to ON, the setting items indicated in
Set the time range using the
Set the timer mode using the
Set the output mode using the
Set each digit for the output time using the corresponding
(If the output time is set to 0.00,
Displayed for modes A, A-1, A-2, A-3, b, and b-1 only.
Set the input signal width using the
Set the NPN/PNP input mode using the
Only displayed for H5CX-A@ and H5CX-A11@ models.
Set the display color using the
Displayed for terminal-block models (H5CX-A@) only.
Set the key protect level using the
(Elapsed
For details, refer to Time Range List below.
(20 ms)
(A)
(Red) (Green) Red-green Green-red
time)
(KP-1)
2. Changes made to settings in function setting mode are enabled for the
operation will continue.
first time when the mode is changed to run mode. Also, when settings
are changed, the timer is reset (time initialized and output turned OFF).
(A-1)
s
(Remaining
(1 ms)
(KP-2)
time)
(A-2)
: Output hold/0.01 to 99.99 s
s
(KP-3)
(A-3)
s
(b)
(KP-4)
keys.
keys.
keys.
is displayed.)
will not be displayed.
keys.
......
keys.
(b-1)
keys.
(KP-5)
keys.
(d)
h
(E)
(F)
keys.
s
(Z)
Display
Time Range List
0 h 01 min to 99 h 59 min
0.1 h to 999.9 h
0.01 s to 99.99 s
(default setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to 99 min 59 s
0.1 min to 999.9 min
1 min to 9999 min
1 h to 9999 h
0.001 s to 9.999 s
Set Value
H5CX-A/-L
19

Related parts for H5CX-L8D-N DC12-24/AC24