NLP65-9620J ARTESYN, NLP65-9620J Datasheet - Page 3

no-image

NLP65-9620J

Manufacturer Part Number
NLP65-9620J
Description
AC/DC Power Supply Dual-OUT 5V/24V 7A/2A 65W 8-Pin
Manufacturer
ARTESYN
Datasheet

Specifications of NLP65-9620J

Input Voltage
85 to 264 V
Output Voltage
5|24 V
Maximum Current Rating
1.4(rms) A
Maximum Output Current
7|2 A
Number Of Outputs
2
Maximum Output Power
65 W
Efficiency
72(Typ) %
Input Frequency
47 to 63 Hz
Operating Temperature
0 to 70 °C
Notes
1 Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65-
2 When the input voltage is less than 90 Vac the operating temperature range is
3 Peak output current lasting less than 60 seconds with duty cycle less than 5%.
4 Figure is peak-to-peak for convection power rating. Output noise
5 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5
6 A minimum load on the main output is required for proper start up. For
7 For optimum reliability, no part of the heatsink should exceed 120
8 CAUTION: Allow a minimum of 1 second after disconnecting line power when
9 This product is only for inclusion by professional installers within other
10 Maximum continuous output power for all multiple output models must not
Model Numbering Options
1 The enclosure version includes: IEC connector, on/off switch, wire harness
2 A Safety earth ground pin and ground choke are available as an option.
3 To order an enclosure kit (unfitted), order the part number LPX80.
+5 V (IA)
+12 V (IB)
–12 V
+5 V (IA)
+15 V (IB)
–15 V
+5 V
+24 V
+12 V
+5 V (IA)
+24 V (IB)
+5 V (IA)
+12 V (IB)
+5 V
+12 V
+15 V
+24 V
X610J must not exceed 62.5 Watts continuous output power with natural
convection. Model NLP65-X620J not to exceed 65 Watts continuous output
power with natural convection. Model NLP65-3322J must not exceed 60 Watts
continuous output power with natural convection.
0
During peak loading, output voltage may exceed total regulation limits.
measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic
capacitor.
Hz to 500 Hz.
multiple outputs and single +5V output, the minimum load on the +5 V is
0.2 A. For single outputs greater than +5 V the minimum load is 0.1 A. To
maintain stated regulation then:
for single output units
I ≥ 0.2 A
for multiple output units
0.25
semiconductor case temperature should exceed 130
making thermal measurements.
equipment and must not be operated as a stand alone product.
exceed 75 Watts (70 watts for NLP65-3322J)with 20 CFM forced air cooling.
output connector and fitted cover. To order, please add the suffix ‘E’ the model
number, e.g. NLP65-9608EJ. See NLP65 enclosure for details.
To order, please add the suffix ‘G’ the model number, e.g. NLP65-X608GJ.
Voltage
Output
°
C to +40
≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2 A.
°
C. The ripple and regulation specifications may not be met.
Max (1)
7.5 A
2.5 A
0.65 A
7.5 A
2.2 A
0.65 A
7.0 A
1.5 A
0.7 A
7 A
2 A
7 A
2.5 A
10 A
5.4 A
4.4 A
2.7 A
Output Current
Peak (3)
9.1 A
3.3 A
0.81 A
9.1 A
2.9 A
0.85 A
9.1 A
2.6 A
1.0 A
9.1 A
2.6 A
9.1 A
3.3 A
13 A
7 A
5.7 A
3.5 A
Fan (10)
8 A
3 A
0.8 A
8 A
2.5 A
0.8 A
8.0 A
2.0 A
1.0 A
8 A
2 A
8 A
3 A
12 A
6.5 A
5.3 A
3.5 A
o
C.
Ripple (4)
o
50 mV
150 mV
120 mV
50 mV
150 mV
150 mV
50 mV
240 mV
120 mV
50 mV
240 mV
50 mV
150 mV
50 mV
120 mV
150 mV
240 mV
C, and no
Regulation (6)
11 Conducted emissions testing were performed using the standard EN55022 set-
12 The NLP65 units with the suffix ‘G’ is the ground pin and ground choke option.
13 All models require a minimum mounting stand-off of 0.25 inches (6.35 mm) in
14 The NLP65-9608J is available with an enclosure. To order an enclosed version,
15 No PFC version, EN61000-3-2 is not applicable to this model.
16 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
17 NOTICE: Some models do not support all options. Please contact your local
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±2.0%
±5.0%
±2.0%
±2.0%
±2.0%
±2.0%
Total
up with a stand alone NLP65 unit placed on a grounded metal plate with a line
choke on the AC input and ground wires (i.e. the wires are looped through an
EMI suppression toroid).
For system compliance it is usually necessary to install an ‘off-the-shelf’ AC
inlet with an integral line filter in the system chassis or to install a line choke
on the input wires as close as possible to AC entry point of the system chasssis.
Please contact the applications group for assistance with EMI compliance.
J2, L6 and JP10 are included. J2 is a safety agency approved grounding pin, L6
is a ground choke and JP10 is a jumper. This option is intended for use in non-
metallic chassis applications where grounding is not possible via the mounting
screws. The ground choke is provided to assist system EMC compliance. When
performing conducted emissions testing on stand alone units, the ‘G’ option
is required to meet level B. To order simply add the suffix ‘G’ to the standard
model number, e.g. NLP65-7608GJ, NLP65-9608GJ. This option is available for
both the PFC and non-PFC versions.
the end use product.
see model numbering options below.
Emerson Network Power representative or use the on-line model number
search tool at http://www.powerconversion.com.
NLP65-7608J
NLP65-7610J
NLP65-3322J
NLP65-7620J
NLP65-7629J
NLP65-7605J
NLP65-7612J
NLP65-7615J
NLP65-7624J
Non-harmonic
Corrected
(15)
NLP65-9608J
NLP65-9610J
NLP65-9620J
NLP65-9629J
NLP65-9605J
NLP65-9612J
NLP65-9615J
NLP65-9624J
Corrected
Harmonic
Embedded Power for
Business-Critical Continuity
NLP65-X608GJ
NLP65-X610GJ
NLP65-X620GJ
NLP65-X629GJ
NLP65-X605GJ
NLP65-X612GJ
NLP65-X615GJ
NLP65-X624GJ
Pin (12, 14, 17)
Ground
Rev.12.12.08_102
NLP65 Series
 of 4

Related parts for NLP65-9620J