D6F02A1110 Omron, D6F02A1110 Datasheet - Page 11

Flow Sensor Mass Air ±3% 3-Pin

D6F02A1110

Manufacturer Part Number
D6F02A1110
Description
Flow Sensor Mass Air ±3% 3-Pin
Manufacturer
Omron
Datasheets

Specifications of D6F02A1110

Accuracy
±3 %
Medium
Air
Maximum Output Voltage
5 V
Typical Operating Supply Voltage
12|15|18|24 V
Sensor Type
Mass
Lead Free Status / Rohs Status
Compliant
Clogged Filter Detection (Configuration 1)
The sensor detects the pressure
drop over the filter. The moment
this drop exceeds a given
threshold, a warning signal
Clogged Filter Detection (Configuration 2)
Filter clogging can be detected,
also using the bypass-like
configuration. The differential
pressure between upstream
and downstream of the filter
grows in proportion to the
Omron Electronic Components Europe BV reserves the right to make any changes to the specifications of the products described in
this brochure at its sole discretion and without prior notice.
6
5
4
3
2
1
0
6
5
4
3
2
1
0
1
1
Warning Signal is sent out
Warning Signal is sent out
3
3
5
5
Months
Months
7
7
9
9
11
11
Filter Replacement
Filter Replacement
Threshold
Threshold
accumulation of dirt in the filter,
and the output voltage of the
sensor located on the bypass
channel increases.
indicating the need for filter
replacement is sent out.
Clogged Filter
Clogged Filter