9-1393792-9 Tyco Electronics, 9-1393792-9 Datasheet - Page 219

no-image

9-1393792-9

Manufacturer Part Number
9-1393792-9
Description
Electromechanical Relay DPDT 3A 24VDC 2.88KOhm Through Hole
Manufacturer
Tyco Electronics
Type
Signal Relayr
Datasheet

Specifications of 9-1393792-9

Contact Arrangement
DPDT
Dc Coil Voltage
24 V
Coil Current
8.33 mA
Mounting
Through Hole
Dimensions are shown for
reference purposes only.
Contact Ratings @ 25 C with relay properly vented.
Remove tape over vent hole after soldering and cleaning.
Arrangements: 2 Form A (DPST-NO) and 2 Form C (DPDT).
Materials: Silver cadmium oxide.
Max. Load Rating:
Min. Load Rating:
Expected Mechanical Life: 5 million operations.
Expected Electrical Life: 100,000 operations at rated load.
ARI 780-86 Endurance Test (section 6.6):
Notes: Vent hole tape must be removed to achieve all listed ratings.
Coil Data
Voltage: 12 through 110VDC and 12 through 277VAC.
Resistance: See Coil Data table.
Nom. Power: AC Coil: 4.0VA; DC Coil: 1.7W.
Coil Temp. Rise: 35 C/W.
Max. Coil Temp.: 155 C.
Duty Cycle: Continuous.
Features
• 30A DPST-NO and DPDT switching capabilities.
• Designed to control compressor loads to 3.5 tons, 25.3 FLA, 110 LRA.
• Extended life – >300,000 operations at 30A, 240VAC (DC coil).
• Meets requirements of UL873 and UL508 spacings.
• Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to-contacts.
• Meets requirements of UL Class F construction.
• UL approved for 600VAC switching (1.5HP).
• Conforms to VDE 0435, 0631, and 0700.
• New screw terminal version (consult factory for availability, ratings).
Initial Dielectric Strength
Between Contacts and Coil: 4,000V rms, 50/60 Hz.
Between Open Contacts: 1,500V rms, 50/60 Hz.
Between Poles: 2,000V rms, 50/60 Hz.
Initial Insulation Resistance
Between Mutually Insulated Elements: 10
Normally Open Contacts:
Normally Closed Contacts:
Normally Open Contacts: 500mA @ 12VAC/VDC.
Normally Closed Contacts: 100mA @ 6VAC/VDC.
HVAC Definite Purpose Contactor Standard
Normally Open Contacts
– .315” (8mm) through air, .375” (9.5mm) over surface.
30A @ 120/277VAC, resistive;
10A @ 600VAC, resistive;
1 HP @ 120VAC, 2.5 HP @ 240VAC;1.5 HP @ 480VAC, 1.5 HP @ 600VAC
110 LRA, 25.3 FLA, @ 240VAC with DC coil
60 LRA, 14 FLA @ 240VAC with AC coil
3A @ 240VAC pilot duty;
20A @ 28VDC;
TV10 @ 120VAC.
VDE Rating (Flange Mount): 25A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
VDE Rating (PC Mount): 30A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
3A @ 28VDC or 277VAC, 2A @ 480VAC, 1A @ 600VAC.
VDE Rating (Flange or PC Mount): 3A @ 400VAC, 30K Ops.
Single Phase/Two Pole (Both poles together switching a single load)
Single Phase Per Pole (Single load per pole)
110 LRA, 25.3 FLA, 200K operations (DC Coil).
110 LRA, 18 FLA, 200K operations (DC Coil).
60 LRA, 14 FLA, 200K operations (AC Coil).
Consult factory regarding ratings for screw terminal versions.
>100,000 operations at 30A, 240VAC (AC coil).
Dimensions are in inches over
(millimeters) unless otherwise
specified.
.
9
(1)
ohms, min. @ 500VDC.
;
T1
L1
L1
T1
L2
Catalog 1308242
L2
Issued 3-03
T2
T2
T92
Two-Pole, 30 Amp
PC Board or Panel Mount Relay
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Coil Data (@ 25 C Coil Temperature)
Ambient Temperature vs. Coil Voltage
Assumptions:
Operate Data
Must Operate Voltage: AC Coil: 80% of nominal voltage or less.
Must Release Voltage: 10% of nominal voltage or more.
Initial Operate Time
Initial Release Time
Max Operating Frequency: 14 operations per minute.
Environmental Data
Temperature Range: Storage: -55 C to +155 C.
Vibration: 0.065” (1.65mm) double amplitude for 10-55 Hz., functional.
Shock, Operational: 10g for 11 ms, 1/2 sine wave pulse with no contact
Shock, Mechanical: 100g for 11 ms, 1/2 sine wave pulse.
Flammability: UL 94V-0.
Mechanical Data
Termination: Printed circuit terminals; .250” (6.35mm) quick connects for
Enclosure: Unsealed, plastic dust cover or immersion cleanable, tape
Weight: 3 oz. (86g) approximately.
Conditions
All parametric, environmental and life tests are performed according to EIA
Standard RS-407-A at standard test conditions (25 C ambient, 20-50% RH,
29.5
Notes
(1) FLA, LRA ratings are compatible with 3.5 ton compressor applications.
(2) Nominal voltage, no coil suppression, excluding bounce.
Nom. Voltage Freq.
Nom. Voltage
1. Thermal resistance = 35 C per Watt (DC only.)
2. Still air.
3. Nominal coil resistance.
4. Max. mean coil temperature = 155 C (change of resistance method).
5. Coil temperature rise due to load = 6.3 C @ 30 amps.
6. Curves are based on 1.7W at 25 C (DC only.)
100
120
File E22575
File LR15734
80
60
40
20
( VAC )
( VDC )
0
Specifications and availability
subject to change.
12
24
1” Hg.) unless otherwise noted.
12
24
70
series
75 80
sealed plastic cover.
coil and contacts; .187” (4.75mm) quick connects for coil
and .250” (6.35mm) quick connects for contacts; or M4
screws with captive pressure plates for coil and contacts.
60
60
85
(2)
(2)
opening > 100 s.
10% ( Ohms )
DC Resist.
: 10 ms typical, (25 ms max. w/bounce).
Operating: AC Coil: -40 C to +65 C.
90
: 15 ms typical, (25 ms max. w/bounce).
350
Applied Coil Voltage (% of Rated Nominal)
10% ( Ohms )
DC Coil: 75% of nominal voltage or less.
DC Resist.
86
95 100 105 110 115 120 125 130 135 140 145 150
36.6
AC Coils ( 4.0VA )
9.1
DC Coils ( 1.7W )
DC Coil: -40 C to +85 C.
File E22575 (type 2,3,4,5)
File No. 5386 (type 1,2,3,4)
Nom. Voltage Freq.
Nom. Voltage
110/120
220/240
250/277
( VAC )
110
( VDC )
48
50/60
50/60
50/60
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
10% ( Ohms )
DC Resist.
10% ( Ohms )
1,390
7,255
DC Resist.
3800
5485
950
P&B
511

Related parts for 9-1393792-9