9-1393792-9 Tyco Electronics, 9-1393792-9 Datasheet - Page 257

no-image

9-1393792-9

Manufacturer Part Number
9-1393792-9
Description
Electromechanical Relay DPDT 3A 24VDC 2.88KOhm Through Hole
Manufacturer
Tyco Electronics
Type
Signal Relayr
Datasheet

Specifications of 9-1393792-9

Contact Arrangement
DPDT
Dc Coil Voltage
24 V
Coil Current
8.33 mA
Mounting
Through Hole
Dimensions are shown for
reference purposes only.
Features
• AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC.
• Contact arrangement up to 4PDT.
• Wide selection of termination and mounting styles.
• PC terminals available.
• Push to test button and indicator lamps.
• KUEP incorporates a blow out magnet for high voltage DC switching.
• KUIP/KUGP are VDE approved.
• Complete line of sockets and DIN rail.
• Class B coil insulation.
Contact Data @ 25°C
Arrangements: See respective ordering information table.
Materials: Fine silver (5 amp) silver-cadmium oxide (10 amp).
Expected Mechanical Life:
Contact Ratings
(All other AC ratings apply KUEP .)
Initial Dielectric Strength
Between Open Contacts: 1,200V rms; KUGP , 3,500V rms.
Between Adjacent Contacts: 2,200V rms.
Between Contacts and Coil: 2,200V rms; KUGP , KUIP , 3,750V rms.
Material
Fine
Silver
Silver-
Cadmium
Oxide
Gold flash available as standard.
Gold diffused and gold alloy on special order.
Arrangement
All
1-2 Pole
KUP
KUIP
KUGP
KUEP
All KUMP
KUMP
3 Pole
KUP
KUIP
4 Pole
KUEP
SPST-NO
KUEP
2PST-NO
KUEP
2PDT
5 amps @ 28VDC or 240VAC
80% PF , 2.5 amp tungsten
@120VAC, 1/2 amp @ 120VDC.
1/6 HP @120VAC, 1/3 HP @
240VAC, 5 FLA, 15 LRA @
250VAC (FLA covered by
30,000 operations).
10 amps @ 28VDC or 240VAC,
80% PF , 5 amp tungsten @
120VAC, 3A 600VAC, 1/2 amp
@ 120VDC.
1/3 HP @ 120VAC, 1/2 HP @
240, 480, and 600VAC, 10 FLA
30 LRA @ 120VAC, 5 FLA,
15 LRA @ 250VAC.(FLA ratings
covered by 30,000 operations)
15 amp @ 277VAC, 80% PF
KUM KUMP
10 amp @ 28VDC or 120VAC,
80% PF , 6 2/3 amp @ 240VAC,
80% PF
10 amp per pole not to exceed
30 amp total @ 28VDC, 120VAC,
80% PF , 6 2/3 amp @ 240VAC,
80% PF
10 amp @ 150VDC
5 amp @ 150VDC
3 amp @ 150VDC
UL/CSA Ratings
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Expected
100,000
100,000
100,000
100,000
100,000
100,000
Life
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
Coil Data
KU
KUP Enclosed Relay
KUIP VDE 8mm Coil to Contacts
KUGP VDE 8mm 3mm Gap Coil to Contacts
KUEP 10 Amp 150VDC Load Switching
KUMP 15 Amp 277VAC
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Coil Data @ 25°C
Voltage: 6 to 110VDC and 6 to 240VAC.
Nominal Coil Power:
Operate Data @ 25°C
Must Operate Voltage:
Operating Time (Excluding Bounce):
Release Time (Excluding Bounce):
Environmental Data
Temperature Range:
DC Volts
Nominal
AC Volts
Nominal
DC Coils: 1.2 Watts - KUP , KUIP , KUMP , 1 - 3 pole; KUEP , 1 pole.
DC Coils: 1.8 Watts - KUP , 4 pole; KUEP , 2 pole; KUGP .
AC Coils: 2.0VA - KUP , KUIP , 1 - 2 pole; KUEP , 1 pole.
AC Coils: 2.7VA - KUP , KUIP , 3 pole; KUEP , 2 pole; KUGP , KUMP .
Operating: Enclosed Relays: -45°C to maximum listed in table below.
Max C°
KUMP
KUGP
KUEP
KUIP
120
240
KUP
110
12
24
48
12
24
5
6
6
File E22575
File LR15734
0435 Registration 1792 (KUIP)
0435 Registration 1792 (KUGP)
License 81.12102.01
series
3-4 pole
DC Coils: 75% of nominal voltage or less.
AC Coils: 85% of nominal voltage or less.
15 milliseconds, typical, at nominal voltage.
10 milliseconds, typical, at nominal voltage.
+45°C
2 pole
3 pole
AC
AC
AC
DC Ohms ± 10%
DC Ohms ± 15%
Open Relays: Add 15°C to maximum listed.
10,000
2,250
1,800
9,110
472
120
21
32.1
24
85
+50°C
4 pole 1-2 pole 1-3 pole
2 pole
6
DC
DC
2VA
1.2 Watt
1-2 pole 1-3 pole
+55°C
1 pole
AC
AC
AC
Nom. I ma DC Ohms ± 10%
Nom. I ma DC Ohms ± 15%
238
187
335
100
168
51
26.7
84
11
17 .5
8.75
+70°C
3 pole
2 pole
1 pole
DC
DC
DC
AC
AC
+75°C
2 pole
6,720
1,260
1,700
7 ,200
DC
320
20
80
72
14
18
4.2
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
1-2 pole
2.7VA
1.8 Watt
+80°C
AC
Nom. I ma
Nom. I ma
360
300
150
460
230
115
75
38
16
24
12
1-3 pole
+95°C
DC
P&B
723