MAX2361EGM-D Maxim Integrated Products, MAX2361EGM-D Datasheet - Page 16

no-image

MAX2361EGM-D

Manufacturer Part Number
MAX2361EGM-D
Description
RF Transmitter Complete Dual-Band Q uadrature Transmitte
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX2361EGM-D

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Complete Dual-Band
Quadrature Transmitters
16
Table 3. Configuration Register (CONFIG)
RCP_TURBO2
IF_PLL_SHDN
VCO_BYPASS
RF_PD_POL
ZERO_BIAS
IF_TURBO_
IF_PD_POL
BIT NAME
LD_MODE
IQ_LEVEL
CHARGE
BUF_DIV
RF_PLL_
______________________________________________________________________________________
SHDN
RCP
ICP
POWER-UP
STATE
00
00
11
1
1
0
1
0
0
1
1
1
1
LOCATION
(0 = LSB)
BIT
9, 8
7, 6
1, 0
15
14
13
12
11
10
5
4
3
2
0 shuts down the IF PLL. This mode is used with an external IF PLL.
0 shuts down the RF PLL. This mode is used with an external RF PLL.
0 for normal operation, 1 turns off the bias current to RFH0 output driver.
1 selects 200mV
1 selects ÷2 on IFLO port; 0 bypasses the divider.
1 bypasses IF VCO and enables a buffered input for external VCO use.
A 2-bit register sets the IF charge-pump current as follows:
00 = 139µA
01 = 192µA
10 = 278µA
11 = 390µA
A 2-bit register sets the RF charge-pump current as follows:
00 = 325µA
01 = 650µA
10 = 738µA
11 = 1063µA
IF phase-detector polarity; 1 selects positive polarity (increasing tuning voltage
on the VCO produces increasing frequency); 0 selects negative polarity
(increasing tuning voltage on the VCO produces decreasing frequency).
RF phase-detector polarity; 1 selects positive polarity (increasing tuning voltage
on the VCO produces increasing frequency); 0 selects negative polarity
(increasing voltage on the VCO produces decreasing frequency).
1 activates turbocharge feature, providing an additional IF charge-pump cur-
rent during frequency acquisition.
Works in conjunction with RCP_TURBO1 (OPCTRL register) to set the turbo-
charge current mode. (See Table 7).
Determines output mode for LOCK detector pin as follows:
00 = test mode, LD_MODE cannot be 00 for normal operation
01 = IF PLL lock detector
10 = RF PLL lock detector
11 = logical AND of IF PLL and RF PLL lock detectors
RMS
input mode; 0 selects 100mV
FUNCTION
RMS
input mode.