LPQ352-(CF) Emerson Network Power, LPQ352-(CF) Datasheet

no-image

LPQ352-(CF)

Manufacturer Part Number
LPQ352-(CF)
Description
Manufacturer
Emerson Network Power
Type
Computerr
Datasheet

Specifications of LPQ352-(CF)

Input Voltage
85 to 264V
Number Of Outputs
4
Input Frequency
47 to 440Hz
Efficiency
75%
Screening Level
Commercial
Product Depth (mm)
127mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Pin Count
25
Lead Free Status / RoHS Status
Compliant
128
350 Watts
LPQ350 Series
• Active power factor correction
• IEC EN61000-3-2 compliance
• Remote sense on 1st and 4th output
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Adjustable floating 4th output
• 2 Supervisory output 5 V and 12 V
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• 135 khz switching frequency
• Cover -C
• Optional with fan cover -CF
• Optional end-mounted fan -CEF
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
Electromagnetic susceptibility: Designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
Americas: (760) 930-4600
Special Features
Environmental
Technical Support: (888) 41-ASTEC or (407) 241-2752
Europe (UK) 44 (1384) 842-211
Total Power:
Input Voltage: 85-264 VAC
# of Outputs:
VDE
UL
CSA
NEMKO EN 60950/EMKO-TUE
CB
CE
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
Power factor
Safety ground leakage
current
Output
Maximum power
Adjustment range
Supervisory output
Hold-up time
Overload protection
Overvoltage protection
Logic Control
Power failure
Remote on/off
DC-OK
Remote sense
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 5
Certificate and report
Mark (LVD)
350 Watts
120-300 VDC
Quad
Electrical Specs
Safety
Asia (HK) 852-2437-9662
85-264 VAC; 120-300 VDC
47-440 Hz
38 A max., cold start @ 25°C
75% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and
radiated EN55022 Class B conducted
and radiated VDE 0878 PT3 Class B
conducted and radiated.
0.99 typical
<0.5 mA @ 50/60 Hz, 264 VAC input
With cover: 350 W with 30 CFM forced
air, (-C) (-CF) (-CEF)
± 5% min. on main: 3.3-24 V on output
4
5 V @ 500 mA regulated, 12 @ 150 mA
x2
20 ms @ 350 W load, 115 VAC nominal
line
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5 V output: 5.7-6.7 VDC.
TTL logic signal goes high 50-150 msec
after 5 V output. It goes low at least 4
msec before loss of regulation
Requires an external contact (N.O or
N.C) to inhibit outputs
TTL logic goes high 50-150 msec after
5 V output. It goes low when there is
loss of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
21310-3336-0001
E186249
LR109492C
P97102061 (74-sec) 203
4048, 4049
rev 12.10.03

Related parts for LPQ352-(CF)

LPQ352-(CF) Summary of contents

Page 1

Watts LPQ350 Series Special Features • Active power factor correction • IEC EN61000-3-2 compliance • Remote sense on 1st and 4th output • Power fail and remote inhibit • Single wire current sharing • Built-in EMI filter • Adjustable ...

Page 2

... Ordering Information Model Output Minimum Number Voltage Load LPQ352 + - 3.3- LPQ353 + - 3.3- Peak current lasting <30 seconds with a maximum 10% duty cycle 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. ...