1102855-3 TE Connectivity, 1102855-3 Datasheet - Page 22

Assembly Tools, HTS Heavy Duty Connectors HTS Tools

1102855-3

Manufacturer Part Number
1102855-3
Description
Assembly Tools, HTS Heavy Duty Connectors HTS Tools
Manufacturer
TE Connectivity
Type
Extractor Toolr
Datasheets

Specifications of 1102855-3

Tyco/amp Hvt Series Crimp Contact Heavy-duty Connectors & Solarlok Photovoltaic Interconnection System
RoHS Compliant
Lead Free Status / RoHS Status
Compliant
For Use With
All Wire Sizes
Lead Free Status / Rohs Status
RoHS Compliant part
20
HTS Industrie Steckverbinder
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
Meaning of the 2nd characteristic numeral
The second numeral describes the protection of the housing against the intrusion of water with harmful effects.
code digit
second
4K
6K
9K
0
1
2
3
4
5
6
7
8
short description
not protected
protected against dripping water
protected against dripping water when the housing is
at an angle of up to 15°
protected against water spray
protected against splash water
protected against splash water with increased
pressure
protected against jets of water
protected against strong jets of water
protected against strong jets of water with increased
pressure
protection against the effects of temporary submersi-
on in water
protection against the effects of continuous submersi-
on in water
Protected against water during high-pressure / jet-
stream cleaning.
Protection degrees against the intrusion of water, designated by the second code digit
definition
Vertically falling drops shall have not harmful effects.
Vertically falling drops shall have not harmful effects
when the enclosure is tiled upto 15°
Water sprayed at an angle up to 60°, shall have no harm-
ful effects
Water splashed against the enclosure from any direction
shall have no harmful effects
Water splashed against the enclosure with increased
pressure from any direction shall have no harmful effects
(Applies acc to DIN 40050 - 9 only for road vehicles)
water splashes against the enclosure from any direction
as a water jet shall have no harmful effects
water splashes against the enclosure from any direction
as a strong water jet shall have no harmful effects
water splashes directly against the enclosure from any
direction as a strong water jet with increased pressure,
shall have no harmful effects (Applies acc to DIN 40050 -
9 only for road vehicles)
Quantity of water that ingresses an enclosure, when it is
temporarily immersed under standardized conditions of
pressure and time, shall have no harmful effects.
Quantity of water that ingresses an enclosure, when it is
continuously immersed under conditions of pressure and
time, shall have no harmful effects. The conditions must,
however be harder than for code digit 7 and agreed bet-
ween user and producer.
Water that is directed against the housing with greatly
increased pressure from any direction must not have any
detrimental effect (Applies acc to DIN 40050 - 9 only for
road vehicles)
HTS Heavy Duty Connectors