W2E200-HK86-01 EBM-Papst Industries Inc, W2E200-HK86-01 Datasheet - Page 6

FAN 225X80MM 115VAC 606CFM

W2E200-HK86-01

Manufacturer Part Number
W2E200-HK86-01
Description
FAN 225X80MM 115VAC 606CFM
Manufacturer
EBM-Papst Industries Inc
Series
W2E200r
Type
AC Fanr

Specifications of W2E200-HK86-01

Current Type
AC
Bearing Type
Ball
Fan Type
Tubeaxial
Size / Dimension
Square - 225mm L x 225mm H x 80mm W
Voltage Rating
115VAC
Power (watts)
80W
Rpm
2800 RPM
Noise
61 dB(A)
Static Pressure
0.482 in H2O (120.0 Pa)
Air Flow
606.0 CFM (17.16m³/min)
Termination
Terminal Block
Weight
4.4 lbs (2kg)
Termination Style
61 dB(A)
Product
Fans
External Height
225mm
External Width
225mm
External Depth
80mm
Supply Voltage
115VAC
Flow Rate
606CFM
Noise Rating
61dBA
Power Connection Type
Terminal
Bearings
Ball
Noise Level
59/61dB
Housing Material
Aluminum Die Cast
Power Rating
64/80W
Product Length (mm)
260mm
Product Height (mm)
80mm
Product Depth (mm)
260mm
Fan Rotation
Counter Clockwise
Brand/series
W2E200
Dimensions
8.86 x 3.15 "
Direction
Exhaust over Struts
Nominal Speed
2550 to 2800 RPM
Power, Rating
80 W
Size
8.86 x 3.15 (225 x 80) In. (mm)
Temperature, Operating, Maximum
+65 °C
Thickness
80 mm
Voltage, Rating
115 VAC
Flow Rate - Imperial
606CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
381-2281
4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
4.2 Connecting the electrical system
4.2.1 Prerequisites
4.2.2 Voltage control
Item no.: 11016-5-9970 · Revision status: KM71618 · Print-out on 03/09/2010 · Created by Y. Uhlmann (VM-TDO) · Page 6 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
W2E200-HK86-01
Install the device according to your application.
Check whether the data on the type plate agree with the connection
data and the data of the operating capacitor.
Before connecting the device, ensure that the supply voltage matches
the operating voltage of the device.
Only use cables designed for current according to the type plate.
CAUTION
Cutting and crushing hazard when removing the fan
from the packaging
DANGER
Electric voltage on the device
Electric shock
CAUTION
Electrical voltage
The fan is a built-in component and features no electrically
isolating switch.
NOTE
Water penetration into leads or wires
Water enters at the cable end on the customers side and can
damage the device.
Connect the device only to circuits that can be switched off
using an all-pole disconnecting switch.
With open loop speed control using transformers or electronic
voltage regulators (e.g. phase angle control), excessive current
may occur.
In addition, noises can occur with phase angle control
depending on the mounting situation.
Carefully lift the fan out of its packaging, only touching the
housing. Make sure to avoid any shock.
Wear safety shoes and cut-resistant safety gloves.
Always install a protective earth.
Check the protective earth.
Only connect the fan to circuits that can be switched off with
an all-pole separating switch.
When working on the fan, you must switch off the
installation/machine in which the fan is installed and secure it
from being switched on again.
Make sure that the cable end is connected in a dry
environment.
Operating instructions
4.2.3 Frequency inverter
4.3 Connection via terminal strip
4.3.1 Connecting cables with terminals
Guide the wires into the terminals, see
chapter 4.4 Connection diagram.
Fit sinusoidal filters that work on all poles (live-live and live-
earth) between the frequency inverter and the motor for
operation with frequency inverters.
Depending on how the device is installed, noises may occur.
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.