MC33889BDW Freescale, MC33889BDW Datasheet - Page 41

MC33889BDW

Manufacturer Part Number
MC33889BDW
Description
Manufacturer
Freescale
Datasheet

Specifications of MC33889BDW

Number Of Transceivers
1
Standard Supported
CAN 2.0
Operating Supply Voltage (max)
18V
Operating Supply Voltage (min)
5.5V
Package Type
SOIC W
Supply Current
45mA
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
28
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC33889BDW
Manufacturer:
FREESCALE Semiconductor
Quantity:
26
Part Number:
MC33889BDW
Manufacturer:
FREESCALE
Quantity:
20 000
Table 8. List of Registers
Register description
Table 9. MCR Register
Table 10. Control bits
Analog Integrated Circuit Device Data
Freescale Semiconductor
MCR
MCTR2
Name
WUR
MCR
INTR
RCR
CAN
LPC
IOR
TIM
Reset condition
0
0
0
0
$000b
Reset
Address
$0 0 0
$0 0 1
$0 1 0
$0 1 1
$1 0 0
$1 0 1
$1 1 0
$1 1 1
MCTR1
0
0
1
1
W
R
Wake-up input register
Reset control register
Mode control register
CAN control register
I/O control register
Low power mode
Interrupt register
Timing register
control register
MCTR0
Description
D3
0
1
0
1
BATFAIL
0
SBC MODE
Enter/leave debug mode
Stop, watchdog off
Write: Control of normal, standby, sleep, and stop modes
Read: BATFAIL flag and other status bits and flags
Write: Configuration of reset voltage level, WD in stop mode, low power
mode selection
Write: CAN module control: TX/RX, Rec only, term VBAT, Normal and
extended modes, filter at L0 input.
Read: CAN failure status bits
Write: HS1 (high-side switch) control in normal and standby mode.
Read: HS1 over temp bit, SHIFT bit (gnd shift above selection), V
below 6.1V, V2 below 4.0 V
Write: Control of wake-up input polarity
Read: Wake-up input, and real time LX input state
Write: TIM1, Watchdog timing control, window or Timeout mode.
Write: TIM2, Cyclic sense and force wake-up timing selection
Write: HS1 periodic activation in sleep and stop modes
Force wake-up control
Write: Interrupt source configuration
Read: INT source
Standby
Normal
D2
POR, RESET
VDDTEMP
Read: CAN wake-up event, Tx permanent dominant
MCTR2
0
(2)
Gnd shift register level selection
DESCRIPTION
Standby mode and BATFAIL
Comment and usage
To enter debug mode, SBC must be in Normal or
D1
leave debug mode, BATFAIL must be at 0.
POR, RESET
MCTR1
GFAIL
0
LOGIC COMMANDS AND REGISTERS
FUNCTIONAL DEVICE OPERATION
(1)
D0
must be still at 1. To
POR, RESET
WDRST
MCTR0
0
SUP
33889
41

Related parts for MC33889BDW