Features
Two Forms of Safety from OMRON:
Safety Light Curtains and Multibeam Safety Sensors
Safety Light Curtains for
Finger Protection
F3SN-A@@@@P14
Presence Detection in Danger Zones
(Horizontal Installation)
F3SN-A@@@@P40/P70
F3SN-B@@@@P40/P70
Safety Light Curtains for
Hand Protection
F3SN-A@@@@P25
F3SN-B@@@@P25
• Lineup includes Type-4 Sensors (F3SN-A/F3SH-A) and
• Protective height equals the Sensor length to perfectly
• Protective height: 189 to 1,822 mm
• Setting Console enabling setting parameters for any model.
• LED bar for beam alignment or easy confirmation in error
• A complete lineup of accessories.
• Operating range: 7 m
• Smallest detectable object:
• Protective height: 189 to 1,125 mm
• Operating range: 10 m
• Smallest detectable object: 40 mm dia. (beam gap: 30 mm) or
• Protective height:
• Operating range: 10 m
• Smallest detectable object:
• Protective height: 217 to 1,822 mm
Safety Light Curtain/Multi-beam Safety Sensor
F3SN-A/F3SN-B/F3SH-A
Type-2 Sensors (F3SN-B) with IEC, EN, and JIS standard
certification.
USA UL compliance for applications for the USA or Canada.
meet user needs.
Operating range: 7 or 10 m
mode.
14 mm dia. (beam gap: 9 mm)
70 mm dia. (beam gap: 60 mm)
F3SN-A: 217 to 1,822 mm
F3SN-B: 217 to 1,777 mm
25 mm dia. (beam gap:15 mm)
Be sure to read the “Safety Precautions” on page 28 and
the “Precautions for All Safety Sensors” .
Multi-beam Safety Sensor for Body Protection
F3SH-A09P03
• Operating range: 10 m
• Number of beams: 4 (beam gap: 300 mm)
CSM_F3SN-A_F3SN-B_F3SH-A_DS_E_3_1
1

Related parts for F3SNA0982P25

F3SNA0982P25 Summary of contents

Page 1

... A complete lineup of accessories. Be sure to read the “Safety Precautions” on page 28 and the “Precautions for All Safety Sensors” . Features Two Forms of Safety from OMRON: Safety Light Curtains and Multibeam Safety Sensors Safety Light Curtains for Finger Protection F3SN-A@@@@P14 • ...

Page 2

... Note: Use models with the following model number suffixes for series connection: -01, -03, -04, and -05 Many Connector Variations Select the type of connector that best suits the machine. (Consult your OMRON representative.) Standard: Model No. Model No. Model No. No model suffix: -01 ...

Page 3

... Safety Light Curtains with model numbers ending in -02 through -05, provided with different connector configurations, are also available as options. Refer to page 2 for details. Consult with your dealer or OMRON representative when ordering these models. F3SH-A Multi-beam Safety Sensors (Type 4) Beam gap ...

Page 4

Safety Light Curtain Model List : F3SN-B@@@@P@@ safety light curtains are also available. F3SN-A@@@@P14(-01) Protective Number Model height of beams F3SN-A0189P14(-01) 189 21 F3SN-A0207P14(-01) 207 23 F3SN-A0225P14(-01) 225 25 F3SN-A0243P14(-01) 243 27 F3SN-A0261P14(-01) 261 29 F3SN-A0279P14(-01) 279 31 F3SN-A0297P14(-01) 297 ...

Page 5

... F3SN-A0967P40(-01) 967 32 F3SN-A0997P40(-01) 997 33 Accessories (Optional) Control Unit Appearance Relay, 3NO + 1NC OMRON offers many Safety Application Controllers to help you build safety circuits. Refer to Safety Application Controller Product Selection and specifications. Protective Number Model height of beams F3SN-A1027P40(-01) 1027 34 F3SN-A1057P40(-01) 1057 ...

Page 6

Setting Console Appearance F39-MC11 Maintenance Tool * Appearance F39-MT11 * For detail, see the product datasheet (Cat. No. E355). Branching Connector Appearance F39-CN1 Cable with Connector on One End (for Emitter and Receiver Set) Appearance Cable length 0 ...

Page 7

External Indicators (Separate Models for Emitters and Receivers) Appearance Specification M12 connector for PNP output Note: These indicators are used for connecting with series-connection type emitters/receivers (models ending in -01). (The Indicator must be secured separately for models ending in ...

Page 8

Multi-beam Sensor Support Stands/Mirror Stands Appearance Specification Stand unit Materials Base:STKM (base) SUS304 (leaf spring) Pipe, bolts and nuts: SUS304 Weight: 11.8 kg Mounting bracket Materials: Aluminum Weight: 250 g Mounting Brackets for Sensors (Optional) Appearance Wall mounting bracket Material: ...

Page 9

Specifications (For details, refer to the instruction manual.) Main Units F3SN-A/F3SH-A Model Stand- F3SN-A@@@@P14 *8 *1 alone Series F3SN-A@@@@P14- Item connection Sensor type Type 4 Safety Light Curtain Setting tool connection Connectable Safety category Category ...

Page 10

... For example, if the beam gap is 9 mm, and the No. of beams is 21, the protective height will be 9 × 189 mm. The model with this protective height is F3SN-A0189P14. *2. F3SN-A@@@@P14- customized model. Consult with your dealer or OMRON representative when ordering this model. *3. Only models ending in -01, -03, -04, or -05 have this output and functionality. ...

Page 11

F3SN-B ( Different from specifications of F3SN-A) Model *6 F3SN-B@@@@P25 Item Sensor type Type 2 Safety Light Curtain Setting tool connection Not connectable Safety category Category Opaque objects: Detection capability diameter Beam gap ...

Page 12

Accessories Control Units Item Model Applicable sensor F3SN-A, F3SN-B, F3SH-A Supply voltage 24 VDC ±10% 1 max. (does not include the sensor’s Power consumption current consumption) 100 ms max. (does not include the sensor’s Operating time response time) ...

Page 13

Connections Wiring for Sensor Only Configuration Wiring for the Manual Reset Mode and the EDM Function Emitter Receiver Emitter cable F39-JC@A-L RS-485(A) (Gray) RS-485(B) (Pink (See (See note 1.) note 1.) Series Connection ( Sets) Using ...

Page 14

An Example of Safety Circuits Where the F3SP-B1P Controller is Used For category 4 rating (F3SN-A, F3SH-A)/category 2 rating (F3SN-B) Emitter Receiver Interlock Test selection OSSD 1 K1 OSSD ...

Page 15

I/O Circuit Diagrams Internal Circuit Diagram Display *3 External indicator output 4 Emitter main circuit Load Gray Pink RS-485(A) RS-485(B) Gray Pink 5 6 Receiver main circuit 2 *3 Receiver main circuit 1 External indicator ...

Page 16

Output waveform of the OSSD outputs The OSSD outputs will be OFF as shown in the following figure in order to perform the OSSD circuit self-test when the light curtain is in the ON-state. The OSSD circuit diagnosis is correct ...

Page 17

... Power indicator (Green These indicators flash to indicate the need for preventive maintenance when the total ON time exceeds 30,000 hours. (Models without this flashing function are also available as options. An “-NT” to the model number. Ask your OMRON representative for details.) F3SN-A/F3SN-B/F3SH-A Error mode ...

Page 18

... Flashing after a lapse of 30,000 hours (F3SN-B only) * These indicators flash to indicate the need for preventive maintenance when the total ON time exceeds 30,000 hours. (Models without this flashing function are also available as options. An “-NT” to the model number. Ask your OMRON representative for details ...

Page 19

Dimensions Main Units Refer to the User’s Manual (SCEE-713) for the dimensions of models with different connector configurations (model numbers ending in “-02” to “-05”). F3SN-A@@@@P@@(-01) F3SN-B@@@@P@@(-01) Dimensions according to the model can be calculated by using the following equations. ...

Page 20

F3SH-A09P03 F3SH-A09P03-01 Intermediate bracket Mounting Precautions 1. The intermediate bracket (3) (see Mounting brackets (intermediate)) is shown on the left-hand side of the sensor as an example. If the intermediate bracket ( the right-hand side of the sensor ...

Page 21

Accessories Mounting Bracket (Top and Bottom) Material: Iron (zinc plating) Note: Provided with the product. Mounting Brackets (Intermediate) Material: Iron (zinc plating) 18 Note: Provided with the product. The number of brackets required depends on the total length of the ...

Page 22

Control Unit F3SP-B1P 9 76 max Emitter Receiver 91 24, M3 10.5 5.9 7 × 4.6 dia. 13 max. 43 5.6 45 max. R2.3 F3SN-A/F3SN-B/F3SH-A Terminal Allocations ...

Page 23

Setting Console F39-MC11 22 52.8 136 Left key Cancel key 50 External Indicators F39-A01PR-L/-D F39-A01PG-L/-D 30 dia. Lighting part 96 104.3 9.2 Waterproof connector Branching Connector (supplied with F39-MC11) F39-CN1 Communications 18 jack 4 M12 3 1 Communications 2 connection ...

Page 24

Spatter Protection Covers F39-HN@@@@-14 F39-HN@@@@-25 F39-HH09-03 Spatter Protection Slit Covers F39-HS@@@@A(B)-14 F39-HS@@@@A(B)-25 F39-HS09A(B)-03 Water-resistant Case F39-HP@@@@-14 F39-HP@@@@-25 F39-HPH09-03 M4 × 12 screw L (depends on the length of housing of each model) 8 R2.8 30 Protection cover ...

Page 25

Wall Mounting Bracket F39-L18 Free-location Bracket F39-L19 5 5.5 dia. 10 Free-location Bracket F39-L20 5.5 dia 15.5 (4.7) M5 up-set hexagon bolt 90° 15.5 12. dia. 30 30° dia. 4.3 14.2 dia. ...

Page 26

Connection Circuit Examples An Example of Safety Circuits Where No Controller Is Used For Category 4 Rating (F3SN-A, F3SH-A)/Category 2 Rating (F3SN-B) Emitter Receiver RS-485(A) (Gray) RS-485(B) (Pink) KM1 S1 S2 KM2 +24 VDC Example of ...

Page 27

Examples of Safety Circuits Where G9SA-300-SC Safety Relay Unit is Connected (1) For only safety light curtain in auto-reset mode For category 4 rating (F3SN-A, F3SH-A)/category 2 rating (F3SN-B) Emitter Receiver F3SN-A/F3SN-B/F3SH-A Series F39-JC@@C-L F39-JC@@C (See note 2.) ...

Page 28

Safety Precautions This catalog is intended as a guide for product selection. Be sure to use the instruction manual provided with the product for actual operation. Regulations and Standards F3SN-A/F3SH-A 1. “Type Certification” specified in the Chapter 44 ...

Page 29

Detection Zone and Intrusion Path Refer to “Precautions for All Safety Sensors” for the installation conditions of Safety Light Curtains. F3SH-A Multi-beam Safety Sensor Install protective structures around the machine so that you must pass through the detection zone ...

Page 30

Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Installation How to Prevent Mutual Interference Series connection ( sets, 240 beams, sensor models ending in -01, -03, -04, and -05 ...

Page 31

Safety-related Functions Interlock Function The auto-reset mode and the manual reset mode are wire selectable features of the F3SN-A/F3SN-B/F3SH-A. Auto-reset Mode After the power is turned ON and none of the beams are interrupted, the OSSD (Output Signal Switching Device) ...

Page 32

Non-safety Output Auxiliary Output The default of this output is the reverse signal of the safety outputs (Dark-ON output). This output can be used for monitoring purposes by connecting device such as a PLC. The auxiliary output ...

Page 33

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...