F3SNA0982P25 Omron, F3SNA0982P25 Datasheet - Page 2

no-image

F3SNA0982P25

Manufacturer Part Number
F3SNA0982P25
Description
Manufacturer
Omron
Datasheet

Specifications of F3SNA0982P25

Lead Free Status / RoHS Status
Supplier Unconfirmed
A New Concept to Meet User Needs
Connect Up To Three Sets in Series without
Mutual Interference
Combine Standard Models with Linking Models with Connectors to
connect up to three sets in series. Wiring is required only for one set
instead of wiring all three sets, as would have been required
previously, to enable protecting all sides of hazardous areas. Mutual
interference protection is also provided.
Many Connector Variations
Select the type of connector that best suits the machine. (Consult your
OMRON representative.)
No model
Standard:
No. suffix
Model No.
suffix: -01
Model No.
suffix: -02
Note: Use models with the following
model number suffixes for series
connection: -01, -03, -04, and -05
Model No.
suffix: -03
Model No.
suffix: -04
Model No.
suffix: -05
Various Safety Functions Built into the Sensor.
Supports Many Safety Circuit Configurations
● Interlocks
● Auto-reset or manual reset
● External relay monitoring
Select the Safety Circuits for the Required Safety
Standards
Build Circuits for Type 4 (F3SN-A/F3SH-A) or Type 2
(F3SN-B) with No Relay Units (2 Relays with Forcibly
Guided Contacts)
LED Bars for Easier Application
Align Beams with the LED Bar for Easier Installation
● Beam Alignment Indicators (Green Only)
Easily Discern Error Mode
Displays to Back Up
Safety
● Error Indication Example
● Reduced Costs and Reduced Space Requirements
A built-in external relay monitor function eliminates the need for Safety Relay Units.
● Reduced Wiring and Easy Maintenance
One-touch connection with connectors on both end to prevent wiring mistakes.
(Red Only)
Safety Light
Curtains
F3SN-A
F3SH-A
F3SN-B
Safety Light
Curtains
F3SN-A
F3SH-A
F3SN-B
F39-JC@A
F39-JC@B
No Safety Relay Units
Connectors
Special Relay Unit
F3SP-B1P
G7SA
F3SN-A/F3SN-B/F3SH-A
Welded relay detection
circuit is possible
with two Relays with
Forcibly Guided Contacts.
Interlock input line or reset input line
wiring mistake or broken line.
Relay welded, return time too long, or external relay
monitor line wiring mistake or broken line.
Communications line (RS-485) wiring mistake,
broken line, or other error.
Control output short, wiring mistake, or control
output circuit fault.
Application not possible.
Sensor ON but not stable.
Dependable application possible.
Contactors
Contactors
Confirmation from
two directions.
Motor
Motor
2