GLK19264-7T-1U-USB-WB-E Matrix Orbital, GLK19264-7T-1U-USB-WB-E Datasheet - Page 57

no-image

GLK19264-7T-1U-USB-WB-E

Manufacturer Part Number
GLK19264-7T-1U-USB-WB-E
Description
DISPLAY
Manufacturer
Matrix Orbital
Datasheet

Specifications of GLK19264-7T-1U-USB-WB-E

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Matrix Orbital
Description
Remembered
Default
Examples
sending a zero will unlock your display as the following tables explains:
NOTES
Always
0
Paranoia allows you to lock the module from displaying information, as
well as enables the protection of the filesystem and module settings.
• Sending a new data lock level will override the previous data lock level.
• Data lock levels may be combined.
Each bit corresponds corresponds to a different lock level, while
0x00
0x50
Bit
0-2
3
4
5
6
7
Hex
Data Lock Level
Reserved
Communication
Speed Lock
Setting Lock
Filesystem Lock
Command Lock
Display Lock
Dec
GLK19264-7T-1U
80
0
01010000
Binary
0
Setting and Command Lock
Description
Should be left 0
When this bit is set (1) the
Baud Rate and I
address are locked
When this bit is set (1)
the display settings such
as backlight, contrast and
GPO settings are locked.
(Internal EEPROM)
When this bit is set (1)
the external EEPROM is
locked, this has the same
effect as the File System
Jumper
When this bit is set (1) all
commands but commands
202/203 are locked. (cmd
lock)
When this bit is set (1) the
module is locked from dis-
playing any new informa-
tion. (text lock)
Description
Unlock
2
C Slave
52

Related parts for GLK19264-7T-1U-USB-WB-E