E5CN-Q2MT-500 AC100-240 Omron, E5CN-Q2MT-500 AC100-240 Datasheet
E5CN-Q2MT-500 AC100-240
Specifications of E5CN-Q2MT-500 AC100-240
E5CNQ2MT500AC100240
Z2410
E5CN-Q2MT-500 AC100-240 Summary of contents
Page 1
... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156) E5CN/E5AN/E5EN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158) http://www ...
Page 2
... Temperature input 1 control output Analog input Option Units E53-CN@@@ Applicable Controller CN: E5CN or E5CN-H 2. Function 1 Blank: None Q: Control output 2 (voltage for driving SSR) P: Power supply for sensor 3. Function 2 Blank: None H: Heater burnout/SSR failure/Heater overcurrent detection (CT1) HH: Heater burnout/SSR failure/Heater overcurrent detection ...
Page 3
... VAC ( VAC/VDC 100 to 240 VAC Silver 24 VAC/VDC Option Units One of the following Option Units can be mounted to provide the E5CN with additional functions. Communications 3-phase heater burnout/SSR failure/ RS-485 Heater overcurrent detection Heater burnout/SSR failure/Heater overcurrent detection Communications RS-485 Heater burnout/SSR failure/Heater ...
Page 4
... Voltage output (for driving SSR) E5CN-Q2TU Current output Relay output 1 Voltage output (for driving SSR) E5CN-Q1LU Current output Analog (current/voltage) Relay output 2 Voltage output (for driving SSR) E5CN-Q2LU Current output Relay output None Voltage output (for driving SSR) E5CN-QTDU Current output Relay output Thermocouple or resistance 1 ...
Page 5
... USB-Serial Conversion Cable Model E58-CIFQ1 Terminal Cover Connectable models Terminal block models Note: The Terminal Cover comes with the E5CN-@@@-500 models. Waterproof Packing Model Y92S-29 Note: The Waterproof Packing is included with the Controller only for models with terminal blocks. Current Transformers (CTs) Hole diameter 5 ...
Page 6
... model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 VAC: 7.5 VA (max.) (E5CN-R2T at 100 VAC: 3.0 VA) E5CN Power 24 VAC/VDC: 5 VA/3 W (max.) (E5CN-R2TD at 24 VAC: 2.7 VA) consump- 100 to 240 VAC (max ...
Page 7
... JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard) Voltage (c)Copyright OMRON Corporation 2008 All Rights Reserved. E5CN/E5CN-U Infrared temperature sensor 115 140 120 165 260 2300 1800 ...
Page 8
... Set value: 5, Upper- and lower-limit with standby sequence X ON Always OFF when the upper-limit and lower-limit hysteresis OFF overlaps OFF OFF 0 (c)Copyright OMRON Corporation 2008 All Rights Reserved. E5CN/E5CN-U Case 2 Case 3 (Always ON) H < < < > > < 0 ⏐H⏐ ≥ ⏐L⏐ ⏐H⏐ > ⏐L⏐ ...
Page 9
... Non-volatile memory (number of writes: 1,000,000 times) Setup Tool CX-Thermo version 4.0 or higher Provided on the bottom of the E5CN. Use this port to connect a computer to the E5CN when using the Setup Tool. An E58-CIFQ1 Setup Tool port USB-Serial Conversion Cable is required to connect the computer to the E5CN. *6 Approved UL 61010-1, CSA C22 ...
Page 10
... ON, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 100 E5CN 250 VAC, 30 VDC 3 (resistive load) cosφ ...
Page 11
... Input power supply B • 100 to 240 VAC TC/Pt universal input • 24 VAC/VDC (no polarity) (c)Copyright OMRON Corporation 2008 All Rights Reserved. E5CN/E5CN-U A heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned. E53-CNPHN2 E53-CNP03N2 ...
Page 12
... Nomenclature E5CN E5CN-U The front panel is the same for the E5CN and E5CN-U. Operation indicators Dimensions E5CN Terminal Models 48 × Waterproof Packing (Accessory) E5CN-U Plug-in Models 48 × Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 http://www.ia.omron.com/ Temperature unit Level Key Mode Key ...
Page 13
... Two, 3.5 dia. 2.36 dia dia. 9 Two, M3 (depth: 4) Armature Lead (c)Copyright OMRON Corporation 2008 All Rights Reserved. E5CN/E5CN-U E54-CT1 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current (50/60 Hz) Number of windings: 400±2 Winding resistance: 18±2 100 ∞ 10 Distortion 1 kΩ ...
Page 14
... Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets Protective Cover for finger protection (Y92A-48G) is also available. http://www.ia.omron.com/ 4.7 69.6 to 77.6 72 × 72 Panel ( mm) 72 × × 48 2.2 4.7 77.3 (to back of E5CN) Terminal Layout/Internal Connections 3 4.5 7.8 (Top View 35.4 Two ...
Page 15
... Under these conditions, control output and alarm output will operate normally. For details on the control range, refer to the E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156). * These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays. ...
Page 16
... Under these conditions, control output and alarm output will operate normally. For details on the control range, refer to the E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). * These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays. ...
Page 17
... Parameters Basic Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156). Starting in manual mode. Press the PF Key for at least Press the O Key less than 1 s. ...
Page 18
... MV at Stop and Error csca Addition off M amad Auto/Manual Select MV Display Addition off Automatic Display Return Time off M (c)Copyright OMRON Corporation 2008 All Rights Reserved. Monitor/Setting PF Monitor/Setting Item Display 4 Item Display 5 PF Setting pf hsu HS Alarm Use (E5AN/E5EN only) a pfd1 hsl HS Alarm Latch ...
Page 19
... Advanced Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN-H/E5AN-H/ E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). Protect Level PID Setting Level Display PID Selection d.pid PID1 1 d.pid PID2 2 d ...
Page 20
... Monitor/Setting PF Item Display 4 Item Display 5 Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item parameters (advanced function setting level). (c)Copyright OMRON Corporation 2008 All Rights Reserved. Press the O and M Keys for at least 3 s. Press the O and M Keys for at least 1 s. ...
Page 21
... Alarm 1 Type M 2 mot Travel Time alh1 Alarm 1 M Hysteresis 0.2 sqr Extraction of Square M Root Enable off M Move to Advanced Function amov Setting Level: Displayed when initial 0 setting/ communications protect is set Move by setting password (−169). (c)Copyright OMRON Corporation 2008 All Rights Reserved. 21 ...
Page 22
... M M och Heater Overcurrent csel Character Select Hysteresis 0 Setting t-u Soak Time Unit a (c)Copyright OMRON Corporation 2008 All Rights Reserved. Monitor/Setting Item Level pfd1 Monitor/Setting Item Monitor/Setting Item 2 pfd2 0 M pfd3 Monitor/Setting Item pfd4 Monitor/Setting Item pfd5 Monitor/Setting Item 5 ...
Page 23
... A class 2 power supply is one tested and certified having the current and voltage of the secondary output restricted to specific levels. *3. The tightening torque for E5CN-U is 0.5 N·m. Precautions for Safe Use Be sure to observe the following precautions to prevent malfunction or adverse affects on the performance or functionality of the product. ...
Page 24
... IP@0 are not waterproof. Front panel: IP66 Rear case: IP20, Terminal section: IP00 (E5CN-U: Front panel: IP50, rear case: IP20, terminals: IP00) Operating Precautions 1. It takes approximately two seconds for the outputs to turn ON from after the power supply is turned ON. Due consideration must be given to this time when incorporating Temperature Controllers in a sequence circuit ...
Page 25
... The Temperature Controller can be removed from the case to perform maintenance without removing the terminal leads. This is possible for only the E5CN, E5AN, and E5EN, and not for the E5CN-U. Check the specifications of the case and Temperature Controller before removing the Temperature Controller from the case. ...
Page 26
... Use crimp terminals when wiring the terminals. • Tighten the terminal screws to a torque of 0.74 to 0.90 N·m, however the terminal screws on the E5CN-U must be tightened to a torque of 0.5 N·m. • Use the following types of crimp terminals for M3.5 screws. ...
Page 27
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...