E5CN-Q2MT-500 AC100-240 Omron, E5CN-Q2MT-500 AC100-240 Datasheet - Page 18

CONTROL TEMP DIGITAL HEAT/COOL

E5CN-Q2MT-500 AC100-240

Manufacturer Part Number
E5CN-Q2MT-500 AC100-240
Description
CONTROL TEMP DIGITAL HEAT/COOL
Manufacturer
Omron
Series
E5CN-Tr
Type
Temperature Controller, Digitalr
Datasheet

Specifications of E5CN-Q2MT-500 AC100-240

Input Type
RTD, Thermocouple (Multiple)
Controller Type
On/Off or Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Voltage
Supply Voltage
100 ~ 240VAC
Size
48mm W x 48mm H (1/16 DIN)
Features
Terminal Cover
Display Type
4 Digit (2)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Communications
-
Other names
E5CN-Q2MT-500-AC100240
E5CNQ2MT500AC100240
Z2410
Press the O Key for at least 1 s.
C
C
alh3
alh2
alt3
tr-h
ev-1
ev-2
alt2
ev-m
tr-t
amov
tr-l
o1-t
100.0
sqr
4-20
none
stop
off
M
off
Move by setting password (−169).
M
M
M
M
M
M
M
M
0.2
0.2
M
M
M
0.0
2
2
1
0
Alarm 2
Hysteresis
Alarm 3 Type
Transfer Output Type
Transfer Output
Upper Limit
Transfer Output
Lower Limit
Linear Current Output
Number of Multi-SP Uses
Two SPs: 1
Four SPs: 2
Move to Advanced
Function Setting Level:
Displayed when initial
setting/communications
protect is set to 0.
Alarm 2 Type
Extraction of Square
Root Enable
Alarm 3
Hysteresis
Event Input
Assignment 1
Event Input
Assignment 2
http://www.ia.omron.com/
Linear output
Monitor/Setting Item Level
Linear output
C
Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level).
25
0
Monitor/Setting
Item Display 1
PF
Advanced Function Setting Level
C
C
spru
rest
sb1n
sb2n
sb3n
at-h
pvad
init
mspu
alfa
at-g
lcma
o-dp
st-b
hbu
hbh
inf
ret
hbl
15.0
0.65
20.0
off
off
n-o
n-o
off
n-o
off
off
M
M
M
M
M
M
M
M
off
M
M
0.1
M
M
M
0.8
M
0.8
M
M
0.0
M
M
M
on
a
m
Parameter Initialization
Standby Sequence
Reset
Heater Burnout Latch
Heater Burnout
Hysteresis
ST Stable Range
Automatic Display
Return Time
Multi-SP Uses
Auxiliary Output 2
Open in Alarm
HB ON/OFF
α
AT Calculated Gain
Limit Cycle MV
Amplitude
Input Digital Filter
Additional PV Display
SP Ramp Time Unit
Auxiliary Output 1
Open in Alarm
AT Hysteresis
Auxiliary Output 3
Open in Alarm
MV Display
Monitor/Setting
Item Display 2
(E5AN/E5EN only)
PF
C
a2on
amad
a3on
a1of
a2of
a3of
istp
colr
a1on
mvse
rlrv
pv-b
a1lt
sero
a3lt
prlt
a2lt
ins1
cjc
red
off
off
off
off
off
off
off
M
M
M
M
rt
off
5.0
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
on
0
0
0
0
0
0
3
Alarm 3 ON Delay
Auto/Manual Select
Addition
PV Change Color
PV Stable Band
Input Shift Type
Move to Protect Level
Time
Alarm 2 ON Delay
Alarm 1 OFF Delay
Alarm 2 OFF Delay
Alarm 3 OFF Delay
MV at Stop and Error
Addition
RT
Alarm 1 Latch
Input Error Output
Cold Junction
Compensation
Method
MB Command
Logic Switching
Alarm 1 ON Delay
Alarm 3 Latch
Alarm 2 Latch
Monitor/Setting
Item Display 3
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Operation for E5@N/E5@N-H
PF
C
C
out1
out2
lbab
sub1
sub2
sub3
lbal
alsp
pvrp
csca
csel
manl
hsu
hsh
lba
none
alm2
t-u
hsl
alm1
alm3
sp-m
ocu
och
M
off
ocl
M
0.1
M
M
8.0
M
3.0
M
M
M
off
on
M
M
M
M
M
M
off
M
M
off
on
M
M
M
o
0.1
M
0
on
m
4
HS Alarm Use
HS Alarm Hysteresis
LBA Detection Time
LBA Band
HS Alarm Latch
Control Output 1
Assignment
LBA Level
Control Output 2
Assignment
Auxiliary Output 1
Assignment
Auxiliary Output 3
Assignment
(E5AN/E5EN only)
Auxiliary Output 2
Assignment
Character Select
Soak Time Unit
Alarm SP Selection
Manual MV
Limit Enable
PV Rate of Change
Calculation Period
Automatic Cooling
Coefficient Adjustment
Heater Overcurrent
Use
Heater Overcurrent
Latch
Heater Overcurrent
Hysteresis
Monitor/Setting
Item Display 4
PF
pfd2
pfd4
pvdp
pfd1
pfd3
pfd5
odsl
spdp
d.ref
ra1m
ra2m
pvst
svst
cmov
ra1
ra2
rac
a-m
0.25
pf
off
off
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
on
M
1
0
0
0
0
0
4
o
0
0
0
0
0
Monitor/Setting Item 2
Monitor/Setting Item 3
Move to Calibration
Level
PF Setting
(E5AN/E5EN only)
Monitor/Setting Item 1
Monitor/Setting Item 4
MV Display Selection
PV Decimal Point
Display
PV Status Display
Function
SV Status Display
Function
Control Output 1
ON/OFF Count
Monitor
ON/OFF Counter
Reset
Monitor/Setting Item 5
"PV/SP" Display
Screen Selection
Display Refresh
Period
Control Output 2
ON/OFF Count
Monitor
Control Output 2
ON/OFF Count
Alarm Set Value
Control Output 1
ON/OFF Count
Alarm Set Value
(E5AN/E5EN only)
Monitor/Setting
Item Display 5
18