E5ER-CT3DW-FLK AC/DC24 Omron, E5ER-CT3DW-FLK AC/DC24 Datasheet

no-image

E5ER-CT3DW-FLK AC/DC24

Manufacturer Part Number
E5ER-CT3DW-FLK AC/DC24
Description
CONTROLLER DIGITAL RS-485 24V
Manufacturer
Omron
Series
E5ERr
Type
Digital Controllerr
Datasheet

Specifications of E5ER-CT3DW-FLK AC/DC24

Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
On/Off
Temperature Range
Selectable, Varies By Input Type
Output Type
Current
Supply Voltage
24VAC/DC
Size
48mm W x 96mm H (1/8 DIN)
Communications
RS-485 (CompoWay/F)
Display Type
LCD; 5 Digit (2), 3 Digit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5ER-CT3DW-FLKAC/DC24
E5ERCT3DWFLKACDC24
E5ER Digital Controllers offer high speed,
high precision, and multiple I/O and use a
5-digit, 3-row LCD display for high visual
clarity.
• A short sampling period of 50 ms enables use in applications
• PV, SP, and MV data is displayed simultaneously in a 3-row,
• Multipoint control, cascade control, and proportional control are
• When using models with CompoWay/F communications, initial
• Equipped with calculation functions as a standard (e.g., square
• DeviceNet Communications
Model Number Structure
■ Model Number Legend
1. Constant values/Program
2. Control method
3. Output 1
4. Output 2
Note: The above model number legend is intended as a functional description of models. Not all possible combinations of functions are available.
E5ER-@@@@@@@@@-@@@
requiring high-speed response.
negative LCD display with a backlight.
possible with a single Controller.
settings can be downloaded and settings can be masked using
Support Software (CX-Thermo version 4.0 or higher).
root calculation and broken-line approximation).
Data setting and monitoring can be performed without any
special programming.
The CX-Thermo Support Software (version 4.0 or higher) can be used to easily set parameters in conversational form.
Digital Controllers
E5ER
Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital
None: Constant values
Blank: Standard, or heating/cooling control
P:
R:
Q:
C:
Blank:None
R:
Q:
C:
Confirm model availability in Ordering Information when ordering.
Controller.
E5AR/E5ER Digital Controller User’s Manual (Cat. No. Z182)
E5AR/E5ER Digital Controller DeviceNet Communication User’s Manual (Cat. No. H124)
Position-proportional control
DPST-NO relay outputs
Pulse voltage and pulse voltage/current outputs
Current and current outputs
Relay
Pulse voltage and pulse voltage/current outputs
Current and current outputs
1
2 3 4 5
6 7 8 9
10
5. Auxiliary outputs
6. Optional function 1
7. Optional function 2
8. Input 1
9. Input 2
10.Communications Method
Refer to E5AR/E5ER Operation for operating
procedures.
Blank:None
4:
T:
Blank:None
3:
Blank:None
D:
B:
F:
W:
Blank:None
W:
Blank:None
FLK: CompoWay/F
DRT: DeviceNet
Refer to Safety Precautions for All E5
Models.
4PST-NO relay outputs
2 transistor outputs
RS-485 communications
4 event inputs
Universal-input and 2 event inputs
Universal-input and FB
Universal-input and universal-input
Universal-input and universal-input
@
CSM_E5ER_DS_E_4_1
R
1

E5ER-CT3DW-FLK AC/DC24 Summary of contents

Page 1

... Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital Controller. E5AR/E5ER Digital Controller User’s Manual (Cat. No. Z182) E5AR/E5ER Digital Controller DeviceNet Communication User’s Manual (Cat. No. H124) Refer to Safety Precautions for All E5 Models. ...

Page 2

... Relay output open, 1 closed) (See note 3.) Relay output 4 No RS-485 (1 open, 1 closed) and 1 current (trans- fer) output E5ER Model Serial commu- E5ER-Q4B E5ER-C4B E5ER-Q43B-FLK (See note 2.) E5ER-C43B-FLK (See note 2.) E5ER-QT3DB-FLK (See note 2.) E5EAR-CT3DB- FLK (See note 2.) E5ER-QC43B-FLK E5ER-QT3DW-FLK E5ER-CT3DW-FLK E5ER-PRTDF E5ER-PRQ43F-FLK 2 ...

Page 3

... Can be switched between close control and floating control. Inspection Results The Inspection Report can be ordered at the same time as the Digital Controller using the following model number. Inspection Report (Sold Separately) Descriptions Inspection Report for E5ER E5ER-K Outputs (control/ transfer) Auxiliary outputs ...

Page 4

... TC.PT Set to TC.PT. IN1 TYPE ANALOG The shaded area indicates the setting status at the time of purchase. E5ER 24 VAC, 50/60 Hz; 24 VDC 11 VA/7 W max. (with maximum load) Current Voltage [mA]   W/Re   5-26 2300.0 1700.0 1800 ...

Page 5

... I/O signal line (level communications line (level (0. MHz) (level line to line (power line, output line (relay output)) (level line to ground (power line, output line (relay output)) (level 3) 0.5 cycle, 100% (rated voltage) E5ER 5 ...

Page 6

... The values in parentheses apply when Thin Cables are used. DeviceNet power supply: 24 VDC DeviceNet power supply VDC 50 mA max. (24 VDC) 64 (includes Configurator when used) 63 CRC error detection Power supplied from DeviceNet communications connector. E5ER Drop line length Total drop line length 6 m max max max max max. ...

Page 7

... Wiring Terminals ■ E5ER Standard Controller Connections E5ER-Q4B A B E53-ARR4 E5ER-AB-500 Auxiliary outputs 24 VAC/DC 100-240 VAC (Relay outputs COM + - 3 2 SUB1 4 3 SUB2 Input power supply 5 4 COM depends on the model. 100 to 240 VAC 6 5 SUB3 or 24 VAC/DC (no polarity SUB4 E5ER-AB-500 ...

Page 8

... OUT3 - 6 6 Current output + + 4-20 mA DC, 500 Ω max 0-20 mA DC, 500 Ω max. (Current) (Voltage) (Thermocouple) (Switch using output type setting.) (Resistance thermometer) E5ER-CT3DB-FLK E5ER-AB-500 E53-ARB4 A B 100-240 VAC B Event inputs EV3 EV4 4 4 EV5 5 EV6 5 E53-ARCC3 + 1 B(+) ...

Page 9

... E5ER-QT3DW-FLK (2-loop Control) E5ER-AW-500 E53-ARB4 VAC/DC 100-240 VAC Event inputs EV3 2 Input power supply depends on the model EV4 100 to 240 VAC VAC/DC (no polarity) 4 EV5 5 EV6 5 E53-ARQC3 + 1 B(+) 6 COM 6 RS-485 - A(-) 2 1 OUT2 + 3 2 Voltage output OUT1 + Voltage output Current output 6 5 4-20 mA DC, 500 Ω max. ...

Page 10

... E5ER DeviceNet-compatible Controller Connections E5ER-QTB-DRT E5ER-AB-500 E53-ARDRT VAC/DC 100-240 VAC DeviceNet Connector - + 1 Red (V+) White (CAN − (Shield) Input power supply depends on the model. Blue (CAN L) 3 100 to 240 VAC Black (V− VAC/DC (no polarity) 5 E53-ARQC OUT2 + 3 2 Voltage output OUT1 Voltage output ...

Page 11

... Input power supply depends (Shield) on the model. 3 Blue (CAN L) 100 to 240 VAC Black (V− VAC/DC (no polarity) 5 E53-ARRR Relay output 2 250 VAC OUT2 Closed OUT1 Open E5ER-PAF-500 E53-ART2 O Potentiometer 1 Auxiliary outputs 1 W (Transistor outputs SUB1 - SUB2 + + - (Current) (Voltage) D (Thermocouple) (Resistance thermometer) E5ER 11 ...

Page 12

... Controllers.) 0 • When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. E5ER MS/NS Indicators Top: MS Bottom: NS DeviceNet communications connector Used to connect the DeviceNet communications cables. ...

Page 13

... Accessories (Order Separately) Terminal Cover E53-COV15 (for E5ER 28.5 10.1 Unit Label Sheet Y92S-L1 Rubber Packing Y92S-P5 (for DIN48 × 96) Order the Rubber Packing separately if it becomes lost or damaged. (Refer to page 3.) The Rubber Packing can be used to achieve an IP66 degree of protection. ...

Page 14

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...