E5ZE-8AQHD1PB-V2 DC24 Omron, E5ZE-8AQHD1PB-V2 DC24 Datasheet - Page 3

no-image

E5ZE-8AQHD1PB-V2 DC24

Manufacturer Part Number
E5ZE-8AQHD1PB-V2 DC24
Description
CONTROLLR TEMP 24V RES THRMOMETR
Manufacturer
Omron
Series
E5ZEr
Type
Temperature Controller, Multipointr
Datasheet

Specifications of E5ZE-8AQHD1PB-V2 DC24

Input Type
RTD
Controller Type
Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Voltage
Supply Voltage
24VDC
Size
65mm W x 243mm H
Display Type
Separate Display Available
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Communications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5ZE-8AQHD1PB-V2DC24
E5ZE8AQHD1PBV2DC24
Characteristics
Note: 1. The measurement accuracy of the E5ZE used with a thermocouple B at 400°C or 750°F max. is not guaranteed. The following
J DISPLAY UNIT
Ratings
E5ZE-8jD1jB
Measurement precision
Adjustable sensitivity
Cooling coefficient
Proportional band
Integral time
Derivative time
Control cycle
Sampling cycle
Dead band/overlap Band
Alarm set range
Fuzzy logic strength
Fuzzy logic scale 1
Fuzzy logic scale 2
SV protection
SV protection time
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Weight
Supply voltage
Operating voltage range
Power consumption
Setting method
Display method
Other functions
2. The measurement accuracy of the E5ZE used with any thermocouple is 1°C/°F. The thermocouple can be used under the fol-
3. Upper limit is 3000.0°C/°F when set from CompoBus/D.
measurement accuracy values are applied to the E5ZE.
K and T at –100°C max. and U:
K and T at –100°F max. and U:
R, S, and W at 200°C max., and B at 1,000°C max.:
R, S, and W at 400°F max., and B at 1,800°F max.:
lowing temperature ranges to increase the measurement accuracy to as high as 0.1°C/°F.
K thermocouple:
T or U thermocouple:
N thermocouple:
J, E, L, or PLII thermocouple: Any temperature
0.0 °C to 1,300.0 °C, 0.0 °F to 2,300.0 °F
400.0 °C to 1,300.0 °C, 700.0 °F to 2,300.0 °F
Thermocouple:
(±0.3% of the measured value or ±2°C, whichever is larger) ±1 digit max.
(±0.3% of the measured value or ±3.6°F, whichever is larger) ±1 digit max.
Platinum resistance thermometer:
(±0.3% of the measured value or ±0.8°C, whichever is larger) ±1 digit max.
(±0.3% of the measured value or ±1.5°F, whichever is larger) ±1 digit max.
0.0°C to 99.9°C or 0.0°F to 99.9°F (0.1° increments), valid for ON/OFF control only.
0.0 to 10.0 (0.1 increments)
0.0°C to 999.9°C or 0.0°F to 999.9°F (0.1° increments)
Cooling: cooling coefficient × proportional band
0 to 3,999 s (1-s increments)
0 to 3,999 s (1-s increments)
Heating or cooling: 1 to 99 s (1-s increments)
Approx. 200 ms/8 words
–999 °C to 999°C or –999°F to 999°F (1° increments)
With 1° increments: –999° to 9,999° (0° to 9,999° with upper/lower limit alarms)
With 0.1° increments: –999.9° to 9,999.9° (0.0° to 9,999.9° with upper/lower limit alarms)
0 to 99% (1% increments)
0.2° to 999.9° (0.1° increments)
0.02° to 99.99° (0.01° increments)
Lithium battery backup
10 years min. at room temperature
20 MΩ at 500 VDC between the FG terminal and analog input terminals
Leakage current of 1 mA max. between the FG terminal and analog input terminals when 500 VAC
is applied for 1 min.
Malfunction: 10 to 55 Hz with 15 m/s
Destruction: 10 to 55 Hz with 20 m/s
Malfunction: 150 m/s
Destruction: 200 m/s
IP00
Case-type Unit: 1,700 g max.
100 to 240 VAC, 50/60 Hz or 24 VDC
85% to 110% of rated supply voltage
Approx. 8 VA at 100 VAC to 12 VA at 420 VAC; approx. 5 W at 24 VDC
Digital setting via Up and Down keys
LED character heights: PV: 15 mm (red); SV: 11 mm (green); UNIT/CH/BK: 11 mm (orange)
Key protection
Display group selection
Display scan function
0.0 °C to 400.0 °C, 0.0 °F to 700.0 °F
±3°C ±1 digit max.
±5.4°F ±1 digit max.
2
2
max. 3 times each in ±X, ±Y, and ±Z directions
max. 3 times each in ±X, ±Y, and ±Z directions
±4°C ±1 digit max.
±7.2°F ±1 digit max.
2
2
in X, Y, and Z directions for 8 min.
in X, Y, and Z directions for 8 min.
E5ZE-8jD1jB