H7ER-NV1-BH Omron, H7ER-NV1-BH Datasheet - Page 31

COUNTER TACH DC VOLT INPUT BLK

H7ER-NV1-BH

Manufacturer Part Number
H7ER-NV1-BH
Description
COUNTER TACH DC VOLT INPUT BLK
Manufacturer
Omron
Series
H7ERr
Datasheets

Specifications of H7ER-NV1-BH

Count Rate
1kHz
Number Of Digits/alpha
5
Input Type
Voltage
Voltage - Supply
24V
Display Type
LCD Backlit
No. Of Digits / Alpha
5
Meter Signal Input
Voltage
Panel Cutout Width
45mm
Meter Function
Tachometer
Signal Input Type
Voltage
Ip/nema Rating
IP66 / NEMA 4
Panel Cutout Height
22.2mm
Counter Supply Voltage
24VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
H7ERNV1BH
Z2743

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H7ER-NV1-BH
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
7. Press the Reset Key before use (not necessary for H7ER-N,-NV,-
■ PCB-mounting Counter
Power Supply
• Use the power supply within the applicable range indicated by the
• The H7E@-N@P changes its mode as shown below depending on
following waveform, while considering the ripple and voltage fluctu-
ations of the circuit power source.
the applied supply voltage.
NV1). (5)
Approx. 2.6
Approx. 2.2
Voltage
(V)
3.6
3
0
No display
Looks darker
Looks normal
Flashes
(5)
Beyond supply voltage
LCD
Tool
(1)
(1)
Normal operation
Normal operation
No operation
(4)
Internal circuit
operation
(3)
Battery
Applicable
range
Battery life
guideline
(2)
3.6 V
2.6 V
EN/IEC Standards
The count or timer input, reset input, and backlight power supply ter-
minals of the no-voltage input or PNP/NPN universal DC voltage
input models (H7E@-N,-N1, H7E@-NV(-H),-NV1(-H)) are not iso-
lated.
A SELV power supply conforming to Appendix H of IEC61010-1
should be used for the count or timer input, reset input and backlight
power supply terminals. A SELV power supply is a power supply for
which the input and output have double or reinforced insulation, and
for which the output voltage is 30 Vrms with 42.4 V peak or 60 VDC
max. (Only the H7E@-NV@-H has a backlight.)
The terminals for count or timer input and reset input for AC/DC
multi-voltage input models have basic insulation.
Connect the reset input terminals to a device that does not have
exposed current-carrying parts and has basic insulation for 240 VAC.
Others
If the indicator keeps flickering or is OFF, the internal battery may be
close to the end of its service life. In such a case, it is suggested that
the battery be replaced.
Battery Replacement
To prevent unwanted reset when replacing the battery, connect the
new battery before disconnecting the old one. Otherwise, the voltage
supplied to the counter circuit drops, causing the present count value
to reset.
When designing the circuit board, providing two extra terminals for
battery connection will make the switch must simpler. See the sche-
matic diagram below:
Wiring polarity must be carefully observed, in order to prevent per-
manent damage to the Counters. Exercise caution when inserting
the Counter in the socket, to prevent reversed polarity.
H7E@-N@P
H7E@-N@P
31