LC4H-R4-AC240V Panasonic Electric Works, LC4H-R4-AC240V Datasheet - Page 9

COUNTER DIGITAL 240VAC OCT 11PIN

LC4H-R4-AC240V

Manufacturer Part Number
LC4H-R4-AC240V
Description
COUNTER DIGITAL 240VAC OCT 11PIN
Manufacturer
Panasonic Electric Works
Series
LC4Hr
Datasheet

Specifications of LC4H-R4-AC240V

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
4
Input Type
Switch Closure or Transistor Switch
Output Type
Switch Closure
Voltage - Supply
100 V ~ 240 V
Display Type
LCD Red/Yellow
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1218

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LC4H-R4-AC240VS
Manufacturer:
Panasonic Electric Works
Quantity:
135
LC4H/-L
2. Output mode
For the output mode, you can choose one of the following seven modes
122
Maintain output
Maintain output
Maintain output
• Maintain output/hold count
• Maintain output/over count I
• Maintain output/over count II
• One shot/over count
• One shot/recount I
• One shot/recount II
• One shot/hold count
Output mode
Over count II
Over count I
Over count
Hold count
Hold count
Recount II
Recount I
One shot
One shot
One shot
One shot
HOLD-A
HOLD-B
HOLD-C
SHOT-A
SHOT-B
SHOT-C
SHOT-D
Output control is maintained after
count-up completion and until resetting.
During that time, the count display does
not change from that at count-up com-
pletion.
Output control is maintained after
count-up completion and until resetting.
However, counting is possible despite
completion of count-up.
Output control is maintained after
count-up completion and until the next
signal enters. However, counting is
possible despite completion of count-
up.
Output control is maintained after
count-up completion for a fixed time
(approx. 1 sec). Counting is possible
despite completion of count-up.
Output control is maintained after
count-up completion for a fixed time
(approx. 1 sec). Counting is possible
despite completion of count-up.
However, reset occurs simultaneous
with completion of count-up. While out-
put is being maintained, restarting of
the count is not possible
Output control is maintained after
count-up completion for a fixed time
(approx. 1 sec). Counting is possible
despite completion of count-up.
However, reset occurs simultaneous
with output OFF.
Output control is maintained after
count-up completion for a fixed time
(approx. 1 sec). During that time, the
count display does not change from
that at count-up completion. Reset
occurs simultaneous with output OFF.
Operation
HOLD-A
HOLD-B
HOLD-C
SHOT-A
SHOT-B
SHOT-C
SHOT-D
* n: Set value
* n: Set value
* n: Set value
* n: Set value
* n: Set value
* n: Set value
* n: Set value
Counting (addition)
Counting (subtraction)
Counting able/unable
Output control
Counting (addition)
Counting (subtraction)
Counting able/unable
Output control
Counting (addition)
Counting (subtraction)
Counting able/unable
Output control
Counting (addition)
Counting (subtraction)
Counting able/unable
Output control
Counting (addition)
Counting (subtraction)
Counting able/unable
Output control
Counting (addition)
Counting (subtraction)
Counting able/unable
Output control
Counting (addition)
Counting (subtraction)
Counting able/unable
Output control
(Example when input mode is either addition or subtraction)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Able
n-3
n-2
n-2
n-1
n-2
n-1
n-2
3
Able
2
2
2
1
1
2
ON
ON
n-2
n-1
n-1
n-1
n-1
2
1
1
1
1
n
0
Approx. 1s
Approx. 1s
Unable
n
0
ON
ON
ON
ON
Reset (automatic)
Able
Able
Able
Able
Able
n-1
n+1
1
n
0
0
n
-1
n
0
n
0
Approx. 1s
Approx. 1s
ON
OFF
OFF
OFF
Reset (automatic)
Reset (automatic)
n+1
n+1
n+1
n-1
-1
-1
-1
1
0
n
0
n
OFF
OFF
Unable
n+2
n+2
n+2
n-2
n-1
n-1
-2
-2
Able
-2
2
1
1
n
0