1217955-1 TE Connectivity, 1217955-1 Datasheet - Page 3

.187 FAST FL AMVAR 0157 TPBR

1217955-1

Manufacturer Part Number
1217955-1
Description
.187 FAST FL AMVAR 0157 TPBR
Manufacturer
TE Connectivity
Datasheets

Specifications of 1217955-1

Product Type
Terminal
Terminal Type
Receptacle
Mating Area Interface Dimensions (mm [in])
4.75 x 0.81 [.187 x .032]
Receptacle Style
Flag
Insulation Support
Insulation Support
Wire/cable Type
Magnet Wire
Insulation Diameter (mm [in])
0.51-1.02 [.020-.040]
Insertion Force
Normal
Finish
Tin
Crimp Type
F-Crimp
Proprietary Name
AMPLIVAR
Board Mount
No
Weld Tab
Without
Wire Range (mm [awg])
0.80-2.00² [18-14]
Stock Thickness (mm [in])
0.41 [0.016]
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Strip
Rev D
Mechanical shock.
Durability.
Mating force.
Unmating force.
Termination tensile strength.
Humidity-temperature cycling.
Temperature life.
NOTE
Test Description
Shall meet visual requirements, show no physical damage, and meet requirements of additional
tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure
2.
No discontinuities of 1 microsecond
or longer duration.
See Note.
See Note.
66.72 N [15 lbf] maximum.
22.24 N [5 lbf] minimum for 1
unmating.
13.3 N [3 lbf] minimum for 6
unmating.
See Figure 4.
See Note.
See Note.
ENVIRONMENTAL
Figure 1 (end)
Requirement
th
st
EIA-364-27,
Method H.
Subject mated specimens to 30 G's
half-sine shock pulses of 11
milliseconds duration. 3 shocks in
each direction applied along 3
mutually perpendicular planes, 18
total shocks.
See Figure 5.
EIA-364-9.
Mate and unmate specimens for 6
cycles at a maximum rate of 500
cycles per hour.
EIA-364-13.
Measure force necessary to mate
specimens at a maximum rate of
12.7 mm [.5 in] per minute.
EIA-364-13.
Measure force necessary to
unmate specimens at a maximum
rate of 12.7 mm [.5 in] per minute.
EIA-364-8.
Determine crimp tensile at a
maximum rate of 25.4 [1 in] per
minute.
EIA-364-31,
Method III.
Subject specimens to 10 cycles (10
days) between 25 and 65
to 100% RH.
EIA-364-17,
Method A,
Test Condition 4,
Test Time Condition C.
Subject mated specimens to 105
for 500 hours.
Procedure
108-2086
/
C at 80
3 of 6
/
C

Related parts for 1217955-1