MAX1228BEEP+ Maxim Integrated Products, MAX1228BEEP+ Datasheet - Page 16

IC ADC 12BIT 300KSPS 20-QSOP

MAX1228BEEP+

Manufacturer Part Number
MAX1228BEEP+
Description
IC ADC 12BIT 300KSPS 20-QSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1228BEEP+

Number Of Bits
12
Sampling Rate (per Second)
300k
Data Interface
MICROWIRE™, QSPI™, Serial, SPI™
Number Of Converters
1
Power Dissipation (max)
727mW
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-QSOP
Number Of Adc Inputs
12
Architecture
SAR
Conversion Rate
300 KSPs
Resolution
12 bit
Interface Type
Serial
Voltage Reference
Internal 4.096 V or External
Supply Voltage (max)
5 V
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
12-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
Table 6. Averaging Register*
* See below for bit details.
Table 7. Reset Register
16
BIT NAME
BIT NAME
AVGON
NSCAN1
NSCAN1
NSCAN0
AVGON
NAVG1
NAVG0
RESET
0
1
1
1
1
______________________________________________________________________________________
x
x
x
0
0
1
1
NSCAN0
NAVG1
7 (MSB)
7 (MSB)
0 (LSB)
0 (LSB)
BIT
BIT
x
0
0
1
1
6
5
4
3
2
1
0
1
0
1
6
5
4
3
2
1
Set to zero to select reset register.
Set to zero to select reset register.
Set to zero to select reset register.
Set to 1 to select reset register.
Set to zero to reset all registers. Set to 1 to clear the FIFO only.
Reserved. Don’t care.
Reserved. Don’t care.
Reserved. Don’t care.
Scans channel N and returns 4 results.
Scans channel N and returns 8 results.
Scans channel N and returns 12 results.
Scans channel N and returns 16 results.
Set to zero to select averaging register.
Set to zero to select averaging register.
Set to 1 to select averaging register.
Set to 1 to turn averaging on. Set to zero to turn averaging off.
Configures the number of conversions for single-channel scans.
Configures the number of conversions for single-channel scans.
Single-channel scan count. (Scan mode 10 only.)
Single-channel scan count. (Scan mode 10 only.)
NAVG0
0
1
0
1
x
Performs 1 conversion for each requested result.
Performs 4 conversions and returns the average for each requested result.
Performs 8 conversions and returns the average for each requested result.
Performs 16 conversions and returns the average for each requested result.
Performs 32 conversions and returns the average for each requested result.
FUNCTION (APPLIES ONLY IF SCAN MODE 10 IS SELECTED)
FUNCTION
FUNCTION
FUNCTION

Related parts for MAX1228BEEP+