583861-7 TE Connectivity, 583861-7 Datasheet - Page 5

10 POS. TWIN LEAF 100 C/L

583861-7

Manufacturer Part Number
583861-7
Description
10 POS. TWIN LEAF 100 C/L
Manufacturer
TE Connectivity
Datasheets

Specifications of 583861-7

Rohs Compliant
YES
Product Type
Housing
Number Of Dual Positions
10
Mounting Ears
With
Centerline (mm [in])
2.54 [0.100]
Housing Material
Polyester GF
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
4.2.
4.3.
Rev D
C.
Requalification Testing
Requalification shall be established by the cognizant divisional engineering function and may consist of
all or any part of the overall qualification program provided that it is conducted within the required time
period.
Quality Conformance Inspection
The applicable quality inspection plan will specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Acceptance
1.
2.
and lower one-sided statistical tolerance limits for 99% reliability at 95% confidence, as
follows. Let Xbar and s denote the sample average and standard deviation, respectively, of
the test data. Let k denote the normal distribution one-sided tolerance factor for 95%
confidence and 99% reliability. The value of k varies with sample size. Values of k are given
in various tables, for example, NBS Handbook 91, Factors for One-Sided Tolerance Limits
for Normal Distribution. Suitability of the normal distribution for representing the data shall
be verified with normal probability plots, goodness of fit tests, etc.
product. When product failure occurs, corrective action shall be taken and samples
resubmitted for qualification.
Test results from development on pre-qualification samples will be used to determine upper
Then the upper one-sided tolerance limit for 99% reliability at 95% confidence is given by
Xbar + ks. The interpretation of this tolerance limit is as follows: based on the test data, and
assuming a normal distribution for the test data, we can be 95% confident that 99% of the
population of values represented by the sample data will not exceed Xbar + ks. For any test
parameter for which there is specified an upper requirement which is not to be exceeded,
satisfactory performance of the product is achieved when the value of Xbar + ks does not
exceed the requirement value.
The lower one-sided tolerance limit for 95% confidence and 99% reliability is given by Xbar
- ks. This has a similar interpretation and corresponding application to lower requirement
values.
Failures attributed to equipment, test setup, or operator deficiencies shall not disqualify the
Sea Level
50,000
70,000
5 ma maximum leakage
No breakdown or flashover
Altitude feet
.100 cl
1000
400
280
Figure 3
Test Voltage, rms
.125 cl
1500
525
375
.156 cl
1800
675
450
108-9031
5 of 8

Related parts for 583861-7