776532-2 TE Connectivity, 776532-2 Datasheet - Page 3

AS 16, 8P PLUG ASSY, RD, KEY 2

776532-2

Manufacturer Part Number
776532-2
Description
AS 16, 8P PLUG ASSY, RD, KEY 2
Manufacturer
TE Connectivity
Datasheets

Specifications of 776532-2

Product Line
AMPSEAL 16
Product Type
Connector
Connector Type
Housing
Mount Angle
Straight
Mount
Free Hanging
Mating Retention Type
Latching
Seal Type
Peripheral and Wire Seals
Centerline (mm [in])
4.50 [0.177]
Number Of Rows
2
Row-to-row Spacing (mm [in])
5.30 [0.209]
Number Of Positions
8
Mating Retention
With
Fluid Type
Water
Contact Type
Socket
Contact Layout
In-Line
Connector Style
Plug
Mating Alignment
With
Housing Color
Gray
Mating Alignment Type
Color Coded, Keyed, Terminal Position Assurance
Housing Material
Thermoplastic - GF
Environmental Protection
With
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Fluid Resistance
Immersion

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
776532-2
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
183
Rev B
Low signal term ination resistance.
Voltage drop.
Insulation resistance.
Random vibration.
Durability.
Term inal retention, axial.
Mating/unm ating force.
Polarizing m ism ating force.
Maintenance aging.
Tem perature life.
Test Description
Contacts shall not dislodge m ore
6 m illiohm s m axim um for 14 and 16
AW G wire.
9 m illiohm s m axim um for 18 AW G
wire.
20 m egohm s m inim um .
No discontinuities.
See Note.
See Note.
than 0.8 m m .
135 N m axim um .
220 N m inim um .
See Note.
See Note.
(AW G) (am peres) m axim um )
W ire
Size
14
16
18
Figure 2 (continued)
ENVIRONMENTAL
MECHANICAL
ELECTRICAL
Requirem ent
Current
Test
13
10
8
Voltage Drop
(m illivolts
100
100
100
SAE J2030 6.3.
SAE J2030 6.2.
Measure connection resistance
across m ated term inals and
subtract bulk resistance of Equal
W ire Lengths (EW L).
SAE J2030 6.4.
Averaged m easurem ents after 30
seconds, 15 m inutes and 30
m inutes of current being applied.
EW L subtracted.
Insulation resistance at 1000 volts
DC adjacent term inals m easured
after 60 seconds or until
stabilization occurs.
EIA-364-28.
Subject m ated specim ens to 21 G's
rm s between 25 to 2000 Hz.
Twenty hours in each of 3 m utually
perpendicular planes.
SAE J2030 6.11.
50 cycles.
IEC 512-8, Test 51a.
Apply axial load of 111 N to
contacts at a m axim um rate of 10 N
per second (or 50 m m per m inute)
and hold for 10 seconds.
SAE J2030 6.9. and 6.10.
Measure force necessary to m ate
and unm ate specim ens at a
m axim um rate of 50 m m per
m inute.
SAE J2030 6.21.
Attem pt to m ate specim en against
polarizing or keying feature.
SAE J2030 6.6.
Insert and rem ove term inal for 8
cycles on 20% of the term inals.
EIA-364-17.
Subject specim ens to 120 ± 3° C
for 500 hours.
Procedure
108-2184
3 of 6

Related parts for 776532-2