794630-8 TE Connectivity, 794630-8 Datasheet - Page 6

PLUG & SOCKET CONNECTOR, PLUG, 8POS, 3MM

794630-8

Manufacturer Part Number
794630-8
Description
PLUG & SOCKET CONNECTOR, PLUG, 8POS, 3MM
Manufacturer
TE Connectivity
Datasheets

Specifications of 794630-8

Peak Reflow Compatible (260 C)
No
Body Material
Nylon
Leaded Process Compatible
No
Mounting Type
Straight PCB Thru-Hole
Connecting Termination
PCB Thru Hole
Connector Type
Plug & Socket
Rohs Compliant
No
Product Type
Plug Housings
Number Of Positions / Contacts
8
Mount Angle
Vertical
Mount
Printed Circuit Board
Pcb Mount Alignment
Without
Product Line
Micro MATE-N-LOK
Mating Retention Type
Latching
Voltage (vac)
250
Current Rating (a)
5
Termination Method
Solder
Termination Post Length (mm [in])
3.18 [0.125]
Solder Tail Contact Plating
Tin-Lead
Number Of Positions
8
Number Of Rows
2
Row-to-row Spacing (mm [in])
3.00 [0.118]
Centerline (mm [in])
3.00 [0.118]
Pcb Mount Retention Type
Compliant Posts
Mating Retention
With
Contact Type
Pin
Contact Termination Type
Through Hole
Contact Layout
Double-Row
Contact Plating, Mating Area, Material
Tin-Lead
Contact Base Material
Brass
Connector Style
Plug
Housing Material
High Temperature Nylon
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
Not ELV/RoHS compliant
Lead Free Solder Processes
Not suitable for lead free processing
Applies To
Printed Circuit Board
Pcb Thickness, Recommended (mm [in])
1.57 [0.062]
Lead Free Status / Rohs Status
No
4.
4.1.
4.2.
4.3.
4.4.
Rev D
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to the product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to
confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan shall specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Specimen Selection
Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. All test groups shall each consist of a minimum of 5
specimens.
Test Sequence
Qualification inspection shall be verified by testing specimens as specified in Figure 2.
108-1836
6 of 7

Related parts for 794630-8