AD9640BCPZ-150 Analog Devices Inc, AD9640BCPZ-150 Datasheet - Page 47

IC ADC 14BIT 150MSP 1.8V 64LFCSP

AD9640BCPZ-150

Manufacturer Part Number
AD9640BCPZ-150
Description
IC ADC 14BIT 150MSP 1.8V 64LFCSP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD9640BCPZ-150

Design Resources
Interfacing ADL5534 to AD9640 High Speed ADC (CN0049)
Number Of Bits
14
Sampling Rate (per Second)
150M
Data Interface
Serial, SPI™
Number Of Converters
2
Power Dissipation (max)
938mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LFCSP
For Use With
AD9640-150EBZ - BOARD EVALUATION AD9640 150MSPS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 26. DC Correction Bandwidth
DC Correction Control Register 0x10C[5:2]
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Bit 1—DC Correction for Signal Path Enable
Setting Bit 1 high causes the output of the dc measurement
block to be summed with the data in the signal path to remove
the dc offset from the signal path.
Bit 0—DC Correction for SM Enable
Bit 0 enables the dc correction function in the signal monitoring
block. The dc correction is an averaging function that can be
used by the signal monitor to remove dc offset in the signal.
Removing this dc from the measurement allows a more accurate
reading.
Signal Monitor DC Value Channel A (Register 0x10D and
Register 0x10E)
Register 0x10D, Bits[7:0]—Channel A DC Value[7:0]
Register 0x10E, Bits[7:0]—Channel A DC Value[13:8]
These read-only registers hold the latest dc offset value computed
by the signal monitor for Channel A.
Signal Monitor DC Value Channel B (Register 0x10F and
Register 0x110)
Register 0x10F Bits[7:0]—Channel B DC Value[7:0]
Register 0x110 Bits[7:0]—Channel B DC Value[13:8]
These read-only registers hold the latest dc offset value computed
by the signal monitor for Channel B.
Signal Monitor SPORT Control (Register 0x111)
Bit 7—Reserved
Bit 6—RMS/MS Magnitude Output Enable
These bits enable the 20-bit rms or ms magnitude measurement
as output on the SPORT.
Bandwidth (Hz)
1218.56
609.28
304.64
152.32
76.16
38.08
19.04
9.52
4.76
2.38
1.19
0.60
0.30
0.15
0.15
0.15
Rev. B | Page 47 of 52
Bit 5—Peak Power Output Enable
Bit 5 enables the 13-bit peak measurement as output on
the SPORT.
Bit 4—Threshold Crossing Output Enable
Bit 4 enables the 13-bit threshold measurement as output on
the SPORT.
Bits[3:2]—SPORT SMI SCLK Divide
The values of these bits set the SPORT SMI SCLK divide ratio
from the input clock. A value of 0x01 sets divide by 2 (default),
a value of 0x10 sets divide by 4, and a value of 0x11 sets divide by 8.
Bit 1— SPORT SMI SCLK Sleep
Setting Bit 1 high causes the SMI SCLK to remain low when the
signal monitor block has no data to transfer.
Bit 0—Signal Monitor SPORT Output Enable
When set, Bit 0 enables the SPORT output of the signal monitor
to begin shifting out the result data from the signal monitor block.
Signal Monitor Control (Register 0x112)
Bit 7—Complex Power Calculation Mode Enable
This mode assumes I data is present on one channel and Q data
is present on the opposite channel. The result reported is the
complex power, measured as
Bits[6:4]—Reserved
Bit 3—Signal Monitor RMS/MS Select
Setting Bit 3 low selects rms power measurement mode. Setting
Bit 3 high selects ms power measurement mode.
Bits[2:1]—Signal Monitor Mode
Bit 2 and Bit 1 set the mode of the signal monitor for data output
to Register 0x116 to Register 0x11B. Setting Bit 2 and Bit 1 to
0x00 selects rms/ms power output; setting these bits to 0x01
selects peak power output; and setting 0x10 or 0x11 selects
threshold crossing output.
Bit 0—Signal Monitor Enable
Setting Bit 0 high enables the signal monitor block.
Signal Monitor Period (Register 0x113 to Register 0x115)
Register 0x113, Bits[7:0]—Signal Monitor Period[7:0]
Register 0x114, Bits[7:0]—Signal Monitor Period[15:8]
Register 0x115, Bits[7:0]—Signal Monitor Period[23:16]
This 24-bit value sets the number of clock cycles over which the
signal monitor performs its operation. Although this register
defaults to 64 (0x40), the minimum value for this register is 128
(0x80) cycles – writing values less than 128 can cause inaccurate
results.
I +
2
Q
2
AD9640

Related parts for AD9640BCPZ-150