MCP4011-502E/SN Microchip Technology, MCP4011-502E/SN Datasheet - Page 28

no-image

MCP4011-502E/SN

Manufacturer Part Number
MCP4011-502E/SN
Description
IC DGTL POT 5K 1CH 8SOIC
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP4011-502E/SN

Package / Case
8-SOIC (3.9mm Width)
Taps
64
Resistance (ohms)
5K
Number Of Circuits
1
Temperature Coefficient
150 ppm/°C Typical
Memory Type
Volatile
Interface
Up/Down
Voltage - Supply
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Resistance In Ohms
5K
Number Of Pots
Single
Taps Per Pot
64
Resistance
5 KOhms
Wiper Memory
Volatile
Digital Interface
Serial (2-Wire)
Operating Supply Voltage
2.5 V or 3.3 V or 5 V
Supply Current
0.045 mA (Typ)
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.8 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP4011-502E/SN
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
MCP4011/2/3/4
4.2
When the device powers up (rising V
Trip Point Voltage (V
restored.
the wiper on POR/BOR.
TABLE 4-1:
While V
may not meet the data sheet specifications (see
Figure
device may be capable of incrementing or decrement-
ing, if a valid command is detected on the CS and U/D
pins.
FIGURE 4-2:
DS21978C-page 28
-202
-502
-103
-503
Package
Code
4-2). The wiper state may be unknown. Also, the
DD
Power-up
Table 4-1
V
1.8V
V
V
< V
DD
TP
SS
Mid-scale
Mid-scale
Mid-scale
Mid-scale
Default
Setting
min
Wiper
POR
DEFAULT POR WIPER
SETTING SELECTION
shows the default value loaded into
(1.8V), the electrical performance
TP
Power-up and Brown-out.
)), the “default” wiper setting is
Wiper
Code
1Fh
1Fh
1Fh
1Fh
DD
R
crosses the
10.0 kΩ
50.0 kΩ
Typical
AB
2.1 kΩ
5.0 kΩ
POR Trip Point (on Rising V
Value
Outside Device Operation
4.3
If the device V
voltage, care must be taken to ensure that the CS and
U/D pins do not “create” any of the serial commands.
When the device V
electrical performance may not meet the data sheet
specifications (see
unknown. Also, the device may be capable of
incrementing or decrementing, if a valid command is
detected on the CS and U/D pins.
When the device voltage rises from below the power-
up trip point (V
range, the wiper state will be forced to the default POR
wiper setting (see
4.4
The serial interface is inactive any time the CS pin is at
V
IH
and all write cycles are completed.
DD
)
Brown Out
Serial Interface Inactive
Wiper Forced to Default POR Setting
DD
TP
Table
) into the valid operation voltage
Figure
is below the specified minimum
DD
© 2006 Microchip Technology Inc.
drops below V
4-1).
4-2). The wiper state may be
MIN
(1.8V), the