DS1856E-020+ Maxim Integrated Products, DS1856E-020+ Datasheet - Page 19

IC RES TEMP-CNTRL 20/20K 16TSSOP

DS1856E-020+

Manufacturer Part Number
DS1856E-020+
Description
IC RES TEMP-CNTRL 20/20K 16TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1856E-020+

Taps
256
Resistance (ohms)
20K
Number Of Circuits
2
Temperature Coefficient
50 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.85 V ~ 5.5 V
Operating Temperature
-40°C ~ 95°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP
Resistance In Ohms
20K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
nally Calibrated Monitors and Password Protection
Dual, Temperature-Controlled Resistors with Inter-
Name of Row
Threshold
Threshold
Threshold
0
1
2
Name of Byte ............. <Read/Write><Volatile><Power-On-Value>
Name of Byte ............. <Read/Write><Nonvolitile><Factory-Default-Setting>
Temp High Alarm ..... <R-all/W-pw2><NV><7FFFh> Temperature measurements above this
Temp Low Alarm....... <R-all/W-pw2><NV><8000h> Temperature measurements below this
Temp High Warning . <R-all/W-pw2><NV><7FFFh> Temperature measurements above this
Temp Low Warning .. <R-all/W-pw2><NV><8000h> Temperature measurements below this
V
V
V
V
Mon1 High Alarm ..... <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon1
Mon1 Low Alarm ...... <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon1
Mon1 High Warning. <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon1
Mon1 Low Warning .. <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon1
CC
CC
CC
CC
High Alarm........ <R-all/W-pw2><NV><FFFFh> Voltage measurements of the V
Low Alarm .......... <R-all/W-pw2><<NV><0000h> Voltage measurements of the V
High Warning.... <R-all/W-pw2><NV><FFFFh> Voltage measurements of the V
Low Warning..... <R-all/W-pw2><<NV><0000h> Voltage measurements of the V
____________________________________________________________________
Measurements below this threshold clear the alarm bit.
Measurements above this threshold clear the alarm bit.
Measurements below this threshold clear the warning bit.
Measurements above this threshold clear the warning bit.
input above this unsigned threshold set its corresponding alarm bit.
Measurements below this threshold clear the alarm bit.
input below this unsigned threshold set its corresponding alarm bit.
Measurements above this threshold clear the alarm bit.
input above this unsigned threshold set its corresponding warning
bit. Measurements below this threshold clear the warning bit.
input below this unsigned threshold set its corresponding warning
bit. Measurements above this threshold clear the warning bit.
input above this unsigned threshold set its corresponding alarm bit.
Measurements below this threshold clear the alarm bit.
input below this unsigned threshold set its corresponding alarm bit.
Measurements above this threshold clear the alarm bit.
input above this unsigned threshold set its corresponding warning
bit. Measurements below this threshold clear the warning bit.
input below this unsigned threshold set its corresponding warning
bit. Measurements above this threshold clear the warning bit.
two's complement threshold set its corresponding alarm bit.
two's complement threshold set its corresponding alarm bit.
two's complement threshold set its corresponding warning bit.
two's complement threshold set its corresponding warning bit.
Register Descriptions
CC
CC
CC
CC
19