Detection Zone and Intrusion Path
Refer to “Precautions for All Safety Sensors” for the installation
conditions of Safety Light Curtains.
F3SH-A Multi-beam Safety Sensor
Use of the Fixed Blanking Function (F3SN-A only)
Safety Distance
Refer to the “Precautions for All Safety Sensors” for calculating the
Safety distance.
Response Time Table
Install protective structures around the machine so that
you must pass through the detection zone of the F3SH-A
to reach a hazardous part of the machine.
If it is possible for an operator to get between the sensor’s
detection zone and the hazardous part of the machine,
design the system so that machinery cannot start up
automatically. Make sure that machinery cannot restart
while the operator is in the hazardous area. Position the
switch for restarting machinery in a location from which
the status of the hazardous area can be seen clearly. The
switch position location must be a place where the switch
cannot be operated from within the hazardous area.
Failure to do so may result in serious injury.
After setting the fixed blanking, check that the F3SN-A
detects a test rod at any position in the detection zone
through which a person can reach the hazardous part of
the machine. If any positions are found by check above,
install protective structures to prevent intrusion, which the
F3SN-A can not detect.
Failure to do so may result in serious injury.
Always maintain a safe distance (S) between the light
curtain and a hazardous part of a machine.
Failure to do so causes the machine to fail to stop before
an operator reaches the dangerous area and may result
in serious injury.
Use of the floating blanking increases the size of the
detection capability. To calculate a safety distance, be
sure to use the increased size of the detection capability.
Failure to do so causes the machine to fail to stop before
an operator reaches the dangerous area and may result
in serious injury.
F3SNA@@@@
P14(-01)
F3SN-A@@@@
P25(-01)
F3SN-B@@@@
P25
Model
Model
180 to 450
459 to 765
774 to 1,080 86 to 120
1,089 to 1,125 121 to 125
217 to 772
787 to 1,297 51 to 85
1,312 to 1,822 86 to 120
Protective
Protective
height
height
(mm)
(mm)
!WARNING
20 to 50
51 to 85
13 to 50
Number of
Number of
beams
beams
10.0
12.5
15.0
15.5
10.0
12.5
15.0
ON to
ON to
Response time
Response time
OFF
OFF
40
50
60
62
40
50
60
OFF to
OFF to
ON
ON
Note: When using the F3SP-B1P, determine the safety distance by
• Response time for series connected types is calculated as follows:
• Response time of F3SP-B1P is 10 ms, operation time is 100 ms.
F3SN-A@@@@
P40(-01)
F3SN-B@@@@
P40
F3SN-A@@@@
P70(-01)
F3SN-B@@@@
P70
(F3SN-A)
For 2 sets:
For 3 sets:
Response time (ON to OFF): Response time of Light curtain 1 +
Response time of Light curtain 2 + 3 ms
Response time (OFF to ON): Response time of Light curtain 1 +
Response time of Light curtain 2 + 12 ms
Response time (ON to OFF): Response time of Light curtain 1 +
Response time of Light curtain 2 + Response time of Light
curtain 3 + 4 ms
Response time (OFF to ON): Response time of Light curtain 1 +
Response time of Light curtain 2 + Response time of Light
curtain 3 + 16 ms
Model
Model
adding the response time of the F3SP-B1P to that of the F3SN
given in the table above.
217 to 757
787 to 1,297 26 to 43
1,327 to 1,807 44 to 60
277 to 757
817 to 1,297 14 to 22
1,357 to 1,777 23 to 30
Protective
Protective
height
height
(mm)
(mm)
F3SN-A/F3SN-B/F3SH-A
7 to 25
5 to 13
Number of
Number of
beams
beams
10.0
12.5
15.0
10.0
12.5
15.0
ON to
ON to
Response time
Response time
OFF
OFF
40
50
60
40
50
60
OFF to
OFF to
ON
ON