Specifications of F3SNA1057P2501

Lead Free Status / Rohs Status
Supplier Unconfirmed
Non-safety Output
Auxiliary Output
The default of this output is the reverse signal of the safety outputs
(Dark-ON output). This output can be used for monitoring purposes
by connecting it to a device such as a PLC.
The auxiliary output can be selected to give one of the following
output operation modes by the F39-MC11. (F39-MC11 cannot be
connected to the F3SN-B.)
Beam Center-line
The beam center-line is the line going through all of the beams. (See
diagram below.) This position is a reference line for measuring safety
distance. Use the line closer to the hazardous area as a reference line
for the safety distance.
• Dark-ON output mode (fixed for the F3SN-B)
• Light-ON output mode
• Light diagnosis mode
• Lockout mode
• Outermost-beam monitoring mode
• Specified-beam mode
• Blanking monitoring mode (F3SN-A only)
Beam
center-line
mark
Safety distance
1 mm
External Indicator Output
(Series-connection type only)
This output can be connected to an external indicator to display one
of the operation modes as selected by the F39-MC11. The default of
this output is Light-ON output. A desired output operation mode can
be selected by using the F39-MC11. (F39-MC11 cannot be
connected to the F3SN-B.)
F3SN-A/F3SN-B/F3SH-A
32