E2E-X2Y1-US Omron, E2E-X2Y1-US Datasheet - Page 29

Proximity Sensors Proximity Sensor

E2E-X2Y1-US

Manufacturer Part Number
E2E-X2Y1-US
Description
Proximity Sensors Proximity Sensor
Manufacturer
Omron
Series
E2Er
Type
Inductive Proximity Sensorr
Datasheets

Specifications of E2E-X2Y1-US

Proximity Sensor Type
Inductive
Proximity Sensor Sensing Distance
2mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Ac Supply Voltage
20 to 264VAC
Mounting
Panel
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Pin Count
2
Maximum Operating Temperature
+ 85 C
Supply Voltage
30 V
Operating Supply Voltage
24 VAC to 240 VAC
Sensing Distance
2 mm
Minimum Operating Temperature
- 40 C
Maximum Output Current
200 mA
Features
High visibility indicator
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
25Hz
Material - Body
Nickel-Plated Brass
Shielding
Shielded
Voltage - Supply
20 VAC ~ 264 VAC
Output Type
SCR-NO
Terminal Type
2-Wire
Package / Case
Cylinder, Threaded - M12
Lead Free Status / Rohs Status
Supplier Unconfirmed
Loads with Large Surge Currents (E2E-X@T@)
If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection
circuit to operate, resulting in operating errors.
● Mounting
Tightening Force
Do not tighten the nut with excessive force.
A washer must be used with the nut.
Note: 1. The allowable tightening strength depends on the distance from the
Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller)
Required Conditions
Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following
conditions. (The meanings of the symbols are given at the right.)
1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following.
2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following.
3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following.
Example
In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity
Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V.
1. V
2. I
3. I
Mutual Interference
When installing Sensors face-to-face or
side-by-side, ensure that the minimum
distances given in the following table are
maintained.
M5
M8
M12
M18
M30
Therefore, I
Connection is thus possible.
OFF
ON
V
I
(If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.)
I
The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as
shown in the following equation.
I
ON
OFF
OUT
ON
ON
2. The following strengths assume washers are being used.
= [V
(1.3 mA) ≥ I
(14.4 V) ≤ V
= (V
≤ V
≥ I
(min.) ≤ I
edge of the head, as shown in the following table. (A is the distance
from the edge of the head. B includes the nut on the head side. If the
edge of the nut is in part A, the tightening torque for part A applies
instead.)
Shielded
Unshielded
Model
CC
leak
CC
CC
(20.4 V) − V
B
− V
− V
OUT
R
ON
R
(min.) (3 mA) ≤ I
leak
Cc
− V
≤ I
(20.4 V) − V
(0.8 mA):
OUT
A
PC
)/R
R
(max.)
(3 V) − V
Dimension
IN
Shielded Models
9
3
R
ON
(3 V) = 17.4 V:OK
PLC
Part B Part A
(4.5 mA):
(4 V)]/R
Part A
IN
180 N·m
Torque
30 N·m
70 N·m
1 N·m
9 N·m
(3 kΩ) = Approx. 4.5 mA
OK
OK
Unshielded Models
Mutual Interference
Note: Values in parentheses apply to Sensors operating at different frequencies.
DC 2-Wire Models
E2E-X@D@
AC/DC 2-Wire Models
E2E-X@T1
DC 3-Wire Models
E2E-X@E@/X@F@
AC 2-Wire Models
E2E-X@Y@
DC 3-Wire Models
E2E-X@C/B@
E2E-C@C/B@
Part B Part A
Torque
12 N·m
Part B
Model
Model
Refer to the following to mount the E2E-CR6, E2E-CR8 and E2E-C1
Unthreaded Cylindrical Models.
When using a set screw, tighten it to a torque of 0.2 N·m max.
(E2E-C1: 0.4 N·m max.)
Shielded
Unshielded
Shielded
Unshielded
Shielded
E2E-CR6
E2E-CR8, E2E-C1
Item
Item
A
B
A
B
A
B
A
B
A
B
V
I
I
R
V
V
I
I
V
Values in parentheses apply to the following PLC
model and Proximity Sensor model.
PLC:
Sensor: E2E-X7D1-N
3 dia.
ON
OFF
leak
OUT
M8
ON
IN
PC
R
CC
20
15
80
60
20
15
80
60
: Output residual voltage of Proximity Sensor
: ON current of PLC (typically 7 mA)
: Input impedance of PLC (3 kΩ)
: Leakage current of Proximity Sensor
: OFF current of PLC (1.3 mA)
: Internal residual voltage of PLC (4 V)
: Power supply voltage (PLC: 20.4 to 26.4 V)
9 to 21 mm
8 to 21 mm
: ON voltage of PLC (14.4 V)
(3 V)
(0.8 mA)
Control output of Proximity Sensor (3 to
100 mA)
C200H-ID212
120 (60)
100 (50)
120 (60)
100 (50)
30 (20)
20 (12)
30 (20)
20 (12)
4 dia.
M12
Dimpled end of
set screw (M3)
(No screws are provided
with the E2E-CR8 or
E2E-C1.)
20
15
200 (100)
200 (100)
110 (60)
110 (60)
50 (30)
35 (18)
50 (30)
35 (18)
M5
M18
(Unit: mm)
5.4 dia.
300 (100)
200 (100)
300 (100)
200 (100)
100 (50)
100 (50)
70 (35)
70 (35)
E2E
M30
29