F3SNA0517P70 Omron, F3SNA0517P70 Datasheet - Page 11

F3SNA0517P70

Manufacturer Part Number
F3SNA0517P70
Description
Manufacturer
Omron
Datasheet

Specifications of F3SNA0517P70

Lead Free Status / Rohs Status
Supplier Unconfirmed
F3SN-B
*1. A safety circuit has been adopted. Please note that the control logic (ON/OFF) may differ from conventionally used logic.
*2. The manual reset mode is set to the “start/restart” interlock. It is impossible to select interlock only or restart interlock only.
*3. No floating blanking or fixed blanking function is provided.
*4. Not provided with the F3SN-B@@@@P70.
*5. The intermediate mounting bracket is supplied with the following types:
*6. Models with different connector configurations are also available as options. Refer to “Many Connector Variations” on page 2.
Item
Sensor type
Setting tool connection
Safety category
Detection capability
Beam gap (P)
Number of beams (n)
Protective height (PH)
Lens diameter
Operating range
Response time (under stable
light incident condition)
Startup waiting time
Power supply voltage (Vs)
Current
consumption
(no load)
Light source
(emitted wavelength)
Effective aperture angle (EAA)
Control outputs (OSSD) *1
Auxiliary output
(non-safety output)
Output operation mode *1
Input voltage
Indicators
Mutual interference prevention
function
Series connections
Test functions
Safety functions *2 *3
Connection method
Protective circuits
Ambient temperature
Ambient humidity
Ambient operating light
intensity
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
Shock resistance
Materials
Weight (packed state)
Accessories
Applicable standards
Types which have the total length of the light curtain from 640 mm to 1280 mm: 1 set for each of emitter and receiver.
Types which have the total length of the light curtain over 1280 mm: 2 sets for each of emitter and receiver.
(
Emitter
Receiver
Emitter
Receiver
Different from specifications of F3SN-A)
Model
*6
Type 2 Safety Light Curtain
Not connectable
Category 2, 1, or B
Opaque objects:
25 mm in diameter
15 mm
13 to 119 (noncontinuous)
217 to 1807 mm
PH = (n − 1) × P + 37 mm
Diameter 9 mm
0.2 to 10.0 m
ON to OFF: 10 to 15 ms max.
OFF to ON: 40 to 60 ms max.
1 s max.
24 VDC ±10% (ripple p-p 10% max.)
Up to 50 beams: 140 mA max., 51 to 85 beams: 155 mA max., 86 beams and more: 170 mA max.
Up to 50 beams: 100 mA max., 51 to 85 beams: 110 mA max., 86 beams and more: 120 mA max.
Infrared LED (870 nm)
Within ±5° for the emitter and receiver at a detection distance of at least 3 m according to IEC 61496-2
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension) , allowable capacity load 0.075 μ F, leak current 2 mA max.
One PNP transistor output, load current 50 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension)
Control output: Light-ON, Auxiliary output: Dark-ON
For test input, interlock selection input, reset input, and external relay monitor input voltages;
ON voltage: 9 to 24 V (sink current: 3 mA max.), OFF voltage: 0 to 1.5 V or open
Power indicator (green), interlock indicator (yellow), lockout indicator (red), test indicator (orange), error mode indicator (3 red),
light intensity level indicator (green: 5 levels)
OFF-state indicator (red), ON-state indicator (green), lockout indicator (red), Optional function indicator (green), error mode
indicator (3 red), light intensity level indicator (green: 5 levels)
Time-shared beam projection system by series connection
M12 connector (8 pins)
Output short-circuit protection, reverse polarity protection
Operating: −10 to 55°C, storage: −30 to 70°C (with no icing or condensation)
Operating/storage: 35% to 95% (with no condensation)
Incandescent lamp: 3000 Ix max. (light intensity on the receiver surface)
Sunlight: 10000 Ix max. (light intensity on the receiver surface)
20 MΩ min. (at 500 VDC)
1000 VAC 50/60 Hz 1 min.
IEC Standard IP65
Malfunction: 10 to 55 Hz, 0.7-mm double amplitude, 20 sweeps in X, Y and Z directions
Malfunction: 100 m/s
Case: Aluminum, end cap: Zinc die-cast, optical cover: PMMA (Acrylic resin)
Weight (g) = (Detection width) × 2.4 + α + β
Detection width of 189 to 639 mm: α = 700, Detection width of 652 to 1,267 mm: α = 800,
Detection width of 1,282 to 1,822 mm: α = 900,
Model with no suffix or −01: β = 0, Model with suffix −02, −03, or −05: β = 100, Model with suffix −04: β = 200
Test rod *4, instruction manual, mounting brackets (top and bottom),
mounting brackets (intermediate) *5, error mode label
IEC61496-1, EN61496-1 Type 2 ESPE (Electro-Sensitive Protective Equipment)
IEC61496-2 Type 2 AOPD (Active Opto-electronic Protective Devices)
• Number of series connected light curtains: Up to 3 sets
• Number of beams: Up to 240 beams
• Length of the series connection cable: 3 m max.
• Self test (when power is ON and period is 1 s or less)
• External test (light emission stop function by test input)
• Auto-reset/manual reset (start/restart interlock)
• EDM (External Device Monitor)
F3SN-B@@@@P25
2
, 1000 times in X, Y and Z directions
Opaque objects:
40 mm in diameter
30 mm
7 to 60 (noncontinuous)
217 to 1807 mm
PH = (n − 1) × P + 37 mm
F3SN-B@@@@P40
F3SN-A/F3SN-B/F3SH-A
Opaque objects:
70 mm in diameter
60 mm
5 to 30
277 to 1777 mm
PH = (n − 1) × P + 37 mm
F3SN-B@@@@P70