F3SNA0517P70 Omron, F3SNA0517P70 Datasheet - Page 13

F3SNA0517P70

Manufacturer Part Number
F3SNA0517P70
Description
Manufacturer
Omron
Datasheet

Specifications of F3SNA0517P70

Lead Free Status / Rohs Status
Supplier Unconfirmed
Connections
Wiring for Sensor Only Configuration
Wiring for the Manual Reset Mode and the EDM Function
Series Connection (Up to 3 Sets)
Using series connection models (model numbers ending in -01, -03,
-04, -05) enables series connection as shown in the figure at the right.
Either stand-alone models and the series connection models can be
used for the light curtains located at the top end.
Note: 1. To maintain sensor performance, please use double-ended
Emitter cable
F39-JC@A-L
2. The F3SN and F3SH cannot be connected in series.
3. Series connection is possible for model numbers ending in
(See
note 1.)
S1
connector cables for series connection which are the length
of F39-JC3B or shorter. Double-ended connector cables
that are longer than F39-JC7B cannot be used for series
connection.
-04 or -05 (with 0.2 m cable with connectors).
Refer to page 2.
(See
note 1.)
S2
Emitter
RS-485(A) (Gray)
RS-485(B) (Pink)
Receiver
K1
K2
K3
Receiver cable
F39-JC@A-D
K1
K2
+24 VDC
0 V
Power
supply
Wiring for the Auto-reset Mode
When the EDM is Not Used
When the EDM is not necessary
(1) Use the F39-MC11 to disable the EDM.
or
(2) Disable the EDM by changing the wiring as shown in the
Note: 1. Use very low load type switches.
S1:
S2:
S3:
K1, K2: Relay that control the dangerous zone, etc.
K3:
figure below, when the auxiliary output is Dark ON.
Emitter
Emitter
Cable with Connectors
on Both Ends (for Emitter)
F39-JCR2B-L,
F39-JCR5B-L,
or
F39-JC3B-L
Cable with Connector
on One End
(for Emitter)
F39-JC@A-L
2. If K3 is not necessary, short-circuit the auxiliary
(See notes 1 and 3.)
External test switch
Interlock/lockout reset switch
Lockout reset switch (If the switch is not necessary,
connect between the reset input and +24 VDC.)
Load, PLC, etc. (used for monitoring)
(See
note 1.)
output with the EDM input.
S1
Emitter
(See
note 1.)
S3
F3SN-A/F3SN-B/F3SH-A
Receiver
F3SN-A@@@@P@@(-@@)*
Receiver
F3SN-A@@@@P@@-01
(or -03, -04, -05) *
Cable with Connectors
on Both Ends (for Receiver)
F39-JCR2B-D,
F39-JCR5B-D,
or
F39-JC3B-D
(See notes 1 and 3.)
Cable with Connector
on One End
(for Receiver)
F39-JC@A-D
(See note 2.)
Receiver
K3
K1
* Series connection is
possible for the F3SN-B.
13

Related parts for F3SNA0517P70