XC3S1200E-4FGG320I Xilinx Inc, XC3S1200E-4FGG320I Datasheet - Page 141

IC FPGA SPARTAN-3E 1200K 320FBGA

XC3S1200E-4FGG320I

Manufacturer Part Number
XC3S1200E-4FGG320I
Description
IC FPGA SPARTAN-3E 1200K 320FBGA
Manufacturer
Xilinx Inc
Series
Spartan™-3Er
Datasheet

Specifications of XC3S1200E-4FGG320I

Number Of Logic Elements/cells
19512
Number Of Labs/clbs
2168
Total Ram Bits
516096
Number Of I /o
250
Number Of Gates
1200000
Voltage - Supply
1.14 V ~ 1.26 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
320-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC3S1200E-4FGG320I
Manufacturer:
Xilinx Inc
Quantity:
10 000
Part Number:
XC3S1200E-4FGG320I
Manufacturer:
XILINX
0
Part Number:
XC3S1200E-4FGG320I
Manufacturer:
XILINX
Quantity:
120
Part Number:
XC3S1200E-4FGG320I
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
18 x 18 Embedded Multiplier Timing
Table 102: 18 x 18 Embedded Multiplier Timing
DS312-3 (v3.8) August 26, 2009
Product Specification
Notes:
1.
2.
3.
Combinatorial Delay
T
Clock-to-Output Times
T
T
T
Setup Times
T
T
T
Hold Times
T
T
T
Clock Frequency
F
MULT
MSCKP_P
MSCKP_A
MSCKP_B
MSDCK_P
MSDCK_A
MSDCK_B
MSCKD_P
MSCKD_A
MSCKD_B
MULT
Symbol
Combinatorial delay is less and pipelined performance is higher when multiplying input data with less than 18 bits.
The PREG register is typically used in both single-stage and two-stage pipelined multiplier implementations.
Input registers AREG or BREG are typically used when inferring a two-stage multiplier.
R
Combinatorial multiplier propagation delay from the A and B
inputs to the P outputs, assuming 18-bit inputs and a 36-bit
product (AREG, BREG, and PREG registers unused)
Clock-to-output delay from the active transition of the CLK
input to valid data appearing on the P outputs when using
the PREG register
Clock-to-output delay from the active transition of the CLK
input to valid data appearing on the P outputs when using
either the AREG or BREG register
Data setup time at the A or B input before the active
transition at the CLK when using only the PREG output
register (AREG, BREG registers unused)
Data setup time at the A input before the active transition at
the CLK when using the AREG input register
Data setup time at the B input before the active transition at
the CLK when using the BREG input register
Data hold time at the A or B input after the active transition
at the CLK when using only the PREG output register
(AREG, BREG registers unused)
Data hold time at the A input after the active transition at the
CLK when using the AREG input register
Data hold time at the B input after the active transition at the
CLK when using the BREG input register
Internal operating frequency for a two-stage 18x18
multiplier using the AREG and BREG input registers and
the PREG output register
(2)
Description
(1)
(2)
(3)
www.xilinx.com
(3)
(3)
(2)
(3)
(3)
3.54
0.20
0.35
0.03
0.04
Min
0.97
0
-
-
-
-5
DC and Switching Characteristics
4.34
Speed Grade
Max
0.98
4.42
270
-
-
-
-
-
-
(1)
3.98
0.23
0.39
0.04
0.05
Min
0.97
0
-
-
-
-4
4.88
Max
1.10
4.97
240
-
-
-
-
-
-
(1)
Units
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
141