E2FM-X2B1-M1 Omron, E2FM-X2B1-M1 Datasheet

Proximity Sensors PNP M12 body M12 DC3 wire

E2FM-X2B1-M1

Manufacturer Part Number
E2FM-X2B1-M1
Description
Proximity Sensors PNP M12 body M12 DC3 wire
Manufacturer
Omron
Series
E2FMr
Datasheet

Specifications of E2FM-X2B1-M1

Maximum Operating Temperature
+ 70 C
Supply Voltage
10 V to 30 V
Mounting Style
Panel
Sensing Distance
2 mm
Minimum Operating Temperature
- 25 C
Features
NO
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
100Hz
Material - Body
Stainless Steel
Shielding
Shielded
Voltage - Supply
10 V ~ 30 V
Output Type
PNP-NO
Terminal Type
Connector
Package / Case
Cylinder, Threaded - M8
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Highly Durable Proximity Sensor for
Tough Environments
• Completely stainless-steel housing
• Aluminum chip immunity
• Embedding installation to metal (steel) fittings
• Chemical resistance certified by Ecolab Europe
• Lineup includes pre-wire models and DC 3-wire NPN output models
Note: Models with a fluororesin coating also use vinyl chloride for the cable material
Features
One-piece completely stainless-steel housing with a face thickness of 0.8 mm
The face thickness is approximately 4 times that of
previous models (E2ES) to enable sensing in even more
severe conditions than ever.
with fluororesin coating.
Proximity Sensor with All-stainless Housing
E2FM
and require separate protection.
Be sure to read Safety Precautions on
page 9.
E2FM
The stainless-steel head
means almost no wear
when cleaned with a
metal brush.
After 3 Minutes
Brush Test
E2EQ
(Spatter-resistant)
Continuous Impact Test
E2ES
The E2ES with a
top wall thickness
of 0.2 mm was
penetrated
10,000 impacts.
More than 20 times the
durability of the E2ES!
after
0.8 mm
E2FM
The E2FM was
not
after 250,000
impacts (depth:
0.26 mm).
penetrated
* Excluding DC 3-wire M8 pre-wired models (E2FM-X1R5B@/-X1R5C@).
Chemical and Detergent Proof
The one-piece completely stainless-
steel housing of the sensing section
withstands the following chemicals
better.
Note: Cannot be used for explosion-proof
• Sodium chloride
• Gasoline
• Dilute sodium hydroxide
• Dilute hydrochloric acid
• Mineral oil
• Barium hydroxide
Any many others
applications.
CSM_E2FM_DS_E_4_2
*
1

Related parts for E2FM-X2B1-M1

E2FM-X2B1-M1 Summary of contents

Page 1

... After 3 Minutes E2FM E2EQ (Spatter-resistant) The stainless-steel head means almost no wear when cleaned with a metal brush. * Excluding DC 3-wire M8 pre-wired models (E2FM-X1R5B@/-X1R5C@). 0.8 mm Continuous Impact Test Chemical and Detergent Proof E2ES E2FM The E2FM was The E2ES with a top wall thickness ...

Page 2

... The material resistance of the tested series (demineralized water) Photometric documentation Inductive Proximity Sensor E2FM to the P3 products used in the test can be considered to be positive according to the cleaning procedure mentioned overleaf. Düsseldorf, 14th February 2006 Ecolab GmbH & Co. OHG i ...

Page 3

... E2FM-X2D1-M1TGJ 0.3M E2FM-X2D1-M1TGJ-T 0.3M E2FM-X5D1-M1TGJ 0.3M E2FM-X5D1-M1TGJ-T 0.3M E2FM-X10D1-M1TGJ 0.3M E2FM-X10D1-M1TGJ-T 0.3M Model E2FM-X1R5D1-M1GJ 0.3M * E2FM-X2D1-M1GJ 0.3M * E2FM-X2D1-M1GJ-T 0.3M * E2FM-X5D1-M1GJ 0.3M * E2FM-X5D1-M1GJ-T 0.3M * E2FM-X10D1-M1GJ 0.3M * E2FM-X10D1-M1GJ-T 0.3M * Output configuration: PNP NO E2FM-X1R5B1 2M E2FM-X2B1 2M E2FM-X5B1 2M E2FM-X10B1 2M Output configuration: PNP NO E2FM-X1R5B1-M1 * E2FM-X2B1-M1 * E2FM-X5B1-M1 * E2FM-X10B1- ...

Page 4

... L-shape 2m XS2F-D422-DC0-A 5m XS2F-D422-GC0-A Note: Refer to Introduction to Sensor I/O Connectors for details. Ratings and Specifications DC 2-Wire (E2FM-X@D@) Size M8 Shielded Model E2FM-X1R5D1-@ E2FM-X2D1-@ E2FM-X5D1-@ E2FM-X10D1-@ Item Sensing distance 1.5 mm±10% 2 mm±10% Set distance 1.4 mm Differential travel 15% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal ...

Page 5

... E2FM Size M8 Shielded Model E2FM-X1R5D1-@ E2FM-X2D1-@ E2FM-X5D1-@ E2FM-X10D1-@ Item Temperature ±20% max. of sensing distance at 23°C in the temperature range of −25 to 70°C. influence Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case ...

Page 6

... B1 Models: PNP open collector, NO (normally open) *2 approaching) Reversed power supply polarity protection, Surge suppressor, Load short-circuit protection, and Reversed output po- Protection circuits larity protection (except the E2FM-X1R5B1-M1) Ambient temperature Operating/Storage: −25 to 70°C (with no icing or condensation) range Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature ± ...

Page 7

... Side length of sensing object: d (mm) E2FM-X10@ 12 Iron 10 8 Stainless steel 6 (SUS304) 4 Brass 2 Aluminum Copper Side length of sensing object: d (mm) E2FM-X@D1-M1GJ(- E2FM-X@D1-M1GJ-T 3 E2FM-X@D1 100 Load current (mA) E2FM-X2@ 3.0 2.5 Iron 2.0 1.5 Stainless 1.0 steel (SUS304) Aluminum Brass 0.5 Copper 0 Side length of sensing object: d (mm) ...

Page 8

... OFF (red) ON Control output OFF Note 1. The load can be connected to either the + side. 2. The E2FM-X@@1-M1GJ-T has no polarity. There is no need to be concerned about the polarity of pins 3 and 4. Timing chart Proximity Sensing area sensor main Proximity sensor circuit 0 100 * There is no reversed output polarity protection diode ...

Page 9

... D is the detection surface size Dimension Model E2FM-X1R5@ E2FM-X2@ E2FM-X5@ E2FM-X10 the cutting chips are pressed down ● Mounting Do not tighten the nut with excessive force. A washer must be used with the nut. Do not use tightening force that exceeds the values in the n m following table ...

Page 10

... Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. E2FM-X2@ 21 dia. M12 × Insulator diameter: 1.4 mm Insulator diameter: 1.2 mm) E2FM-X10@ 42 dia Insulator diameter: 1.75 mm Insulator diameter: 1.75 mm) E2FM-X2D@-M1GJ-@ M12 × dia. M12 × E2FM-X10D@-M1GJ-@ 42 dia. M12 × E2FM (Unit: mm 6-dia ...

Page 11

... Four operation indicators (yellow) E2FM-X5@@- dia Two clamping 24 M18 × 1 nuts Mounting Hole Dimensions Dimension F (mm) F E2FM-X2@@-M1 21 dia. M12 × E2FM-X10@@-M1 42 dia. M12 × 1 Four operation indicators (yellow M12 M18 +0.5 +0.5 +0.5 8.5 dia. 12.5 dia. 18 ...

Page 12

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords