EMC1046-6-AIZL-TR SMSC, EMC1046-6-AIZL-TR Datasheet - Page 28

no-image

EMC1046-6-AIZL-TR

Manufacturer Part Number
EMC1046-6-AIZL-TR
Description
Board Mount Temperature Sensors Temp Sensor with Intrnl Snsr 2 Remote
Manufacturer
SMSC
Datasheet

Specifications of EMC1046-6-AIZL-TR

Full Temp Accuracy
+/- 0.25 C, +/- 0.5 C
Package / Case
TSSOP-10
Digital Output - Bus Interface
Serial (2-Wire)
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EMC1046-6-AIZL-TR
Manufacturer:
SMSC
Quantity:
20 000
Company:
Part Number:
EMC1046-6-AIZL-TR
Quantity:
479
ADDR
1Bh
ADDR.
Revision 0.69 (06-29-09)
5.8
5.9
22h
R/W
R-C
R/W
R/W
External Diode Fault Register
Consecutive ALERT Register
The One Shot Register is used to initiate a one shot command. Writing to the one shot register, when
the device is in standby mode and BUSY bit (in Status Register) is ‘0’, will immediately cause the ADC
to update all temperature measurements. Writing to the One Shot Register while the device is in active
mode will have no affect.
The External Diode Fault Register indicates which of the external diodes caused the FAULT bit in the
Status Register to be set. These bits are cleared when read if the error condition has been removed.
Bit 6 - E6FLT - This bit is set if the External Diode 6 channel reported a diode fault.
Bit 5 - E5FLT - This bit is set if the External Diode 5 channel reported a diode fault.
Bit 4 - E4FLT - This bit is set if the External Diode 4 channel reported a diode fault.
Bit 3 - E3FLT - This bit is set if the External Diode 3 channel reported a diode fault.
Bit 2 - E2FLT - This bit is set if the External Diode 2 channel reported a diode fault.
Bit 1 - E1FLT - This bit is set if the External Diode 1 channel reported a diode fault.
The Consecutive ALERT Register determines how many times an out-of-limit error or diode fault must
be detected in consecutive measurements before the interrupt status registers are asserted.
Each out of limit error and diode fault condition has its own counter associated with it. Each counter
is incremented whenever the corresponding channel exceeds the appropriate limit. Additionally, each
counter is reset if the condition has been removed. (i.e. if External Diode 1 exceeds its high limit, it
will increment the high counter. If, on the next measurement, it experiences a diode fault, the high limit
counter will be reset and the diode fault counter will be incremented).
When the consecutive alert counter reaches its programmed value then the STATUS bit(s) for that
channel and the error condition will be set to ‘1’. Measurements will continue normally.
For example, if the CALRT[2:0] bits are set for 4 consecutive alerts on an EMC1046/EMC1047 device,
the high limits are set at 70°C, and none of the channels are masked, then the status bits will be
asserted after the following four measurements:
1. Internal Diode reads 71°C and both external diodes read 69°C. Consecutive alert counter for INT
REGISTER
Diode Fault
is incremented to 1.
External
Consecutive
REGISTER
ALERT
B7
-
TIME
OUT
Table 5.11 External Diode Fault Register
Table 5.12 Consecutive ALERT Register
B7
E6FLT
B6
B6
-
1°C Multiple Temperature Sensor with Beta Compensation and Hottest of Thermal Zones
DATASHEET
E5FLT
B5
B5
-
28
E4FLT
B4
B4
-
E3FLT
B3
CAL
RT2
B3
E2FLT
CAL
RT1
B2
B2
CAL
RT0
B1
E1FLT
SMSC EMC1046/EMC1047
B1
B0
-
B0
-
Datasheet
DEFAULT
DEFAULT
70h
00h

Related parts for EMC1046-6-AIZL-TR