EMC1002-1-ACZT-TR SMSC, EMC1002-1-ACZT-TR Datasheet

no-image

EMC1002-1-ACZT-TR

Manufacturer Part Number
EMC1002-1-ACZT-TR
Description
Board Mount Temperature Sensors Dual Zone SMBus Temp Snsr
Manufacturer
SMSC
Datasheet

Specifications of EMC1002-1-ACZT-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
PRODUCT FEATURES
General Description
The EMC1002 is an SMBus temperature sensor that
monitors up to two temperature zones and can generate
two system interrupts. With ±1
accuracy, the EMC1002 provides a low-cost solution for
critical temperature monitoring applications. Extended
features include automatic resistance error correction
and programmable ideality factor configuration
eliminating both major sources of temperature
m e a s u r e m e n t e r r o r.
temperature-to-digital converter provides superb
linearity, excellent noise immunity and repeatable
temperature readings.
The EMC1002 generates two separate interrupts with
programmable thermal trip points. The THERM output
operates as a thermostat with programmable threshold
and hysteresis. The ALERT output can be configured
as a maskable SMBus alert with programmable
window comparator limits, or a second THERM output.
The EMC1002 is pin compatible with the ADT7461,
ADM1032, LM99, and the MAX6649.
SMSC EMC1002
1.Patents pending.
DN
DP
Temp Diode
Switching
Current
Internal
1
T h e 11 - b i t s i g m a d e l t a
delta-sigma
11-bit
ADC
°C
measurement
Remote Temp
Internal Temp
Simplified Block Diagram
Register
Register
DATASHEET
EMC1002
Status Register
Features
Applications
Resistance Error Correction
Ideality Factor Configuration
Select 1 of 4 SMBus addresses with external resistor
Remote Thermal Zones
Internal Thermal Zone
Maskable Interrupt using ALERT
One-shot Command during standby
Programmable temperature conversion rate
Extended temperature
Over-limit filtering with consecutive counter
Small 8-pin MSOP lead-free RoHS Compliant
Desktop and Notebook Computers
Smart batteries
Industrial/Automotive
Other Electronic Systems
— ±1°C Accuracy (40°C to 80°C)
— 0.125°C resolution
— ±3°C Accuracy (0°C to 85°C)
package
1°C Dual SMBus Sensor
with Resistance Error
Correction
EMC1002
Address Pointer Register
Conversion Rate Register
Configuration Register
High Limit Registers
Low Limit Registers
THERM Limit Register
THERM Hysteresis Register
Interrupt Masking
(-64°C to 191°C)
Revision 1.4 (12-18-07)
SMCLK
THERM
SMDATA
ALERT
available
Datasheet

Related parts for EMC1002-1-ACZT-TR

EMC1002-1-ACZT-TR Summary of contents

Page 1

... PRODUCT FEATURES General Description The EMC1002 is an SMBus temperature sensor that monitors up to two temperature zones and can generate two system interrupts. With ±1 accuracy, the EMC1002 provides a low-cost solution for critical temperature monitoring applications. Extended features include automatic resistance error correction ...

Page 2

... EMC1002-1-ACZL-TR FOR 8 PIN, MSOP LEAD-FREE ROHS COMPLIANT PACKAGE (Fixed Address, Tape and Reel) EMC1002-2-ACZL-TR FOR 8 PIN, MSOP LEAD-FREE ROHS COMPLIANT PACKAGE (Variable Address, Tape and Reel) See Evaluation Board available upon request. (EVB-EMC1002) 80 ARKAY DRIVE, HAUPPAUGE, NY 11788 (631) 435-6000, FAX (631) 273-3123 Copyright © ...

Page 3

... Logic output that can be used to turn on/off a fan or throttle a CPU clock in the event of an over-temperature condition. This is an open-drain output. For the EMC1002-2, this pin is sampled following power up and the value of the pull-up resistor determines the SMBus slave address per Table 1.2 on page 3 ...

Page 4

... Revision 1.4 (12-18-07) 1°C Dual SMBus Sensor with Resistance Error Correction Table 1.3 Absolute Maximum Ratings pins 4 DATASHEET Datasheet RATING UNIT -0.3 to 5.0 V -0.3 to 5 °C -40 to +125 °C -55 to +150 Refer to JEDEC Spec. J-STD-020 TBD °C/W 109.6 2000 V SMSC EMC1002 ...

Page 5

... SMBus Interface (SMDATA,SMCLK) Input High Level Input Low Level Input High/Low Current Hysteresis Input Capacitance Output Low Sink Current SMBus Timing Clock Frequency SMSC EMC1002 Table 2.1 Electrical Characteristics = -40°C to +125°C, Typical values 27°C unless otherwise noted A A SYMBOL MIN TYP ...

Page 6

... BUF T 0.6 HD:STA T 0.6 SU:STA T 0.6 SU:STO T 0.3 HD:DAT T 100 SU:DAT T 1.3 LOW T 0.6 HIGH T * 300 300 R Note C 0.6 400 b )+50nS SMB 6 DATASHEET Datasheet UNITS CONDITIONS 50 ns μ s μ s μ s μ s μ μ s μ *Min = 20+0. *Min = 20+0. 2.1 pF SMSC EMC1002 ...

Page 7

... Datasheet Chapter 3 System Management Bus Interface Protocol A host controller, such as an SMSC I/O controller, communicates with the EMC1002 via the two wire serial interface named SMBus. The SMBus interface is used to read and write registers in the EMC1002, which is a slave-only device. A detailed timing diagram is shown in ...

Page 8

... The EMC1002 supports stretching of the SMCLK signal by other devices on the SMBus but will not perform this operation itself. The EMC1002 has an SMBus timeout feature. Bit 7 of the Consecutive Alert register enables this function when set to 1 (the default setting is 0) ...

Page 9

... Run Mode: In this mode, the EMC1002 continuously converts temperature data and updates its registers. The rate of temperature conversion is configured as shown in Register," on page Standby Mode: In this mode, the EMC1002 is placed in standby to conserve power as described in 4.7, "Standby Mode," on page 4.1 Temperature Monitors Thermal diode temperature measurements are based on the change in forward bias voltage (Δ ...

Page 10

... The higher the temperature measured, the greater the error introduced. The EMC1002 provides a 6-bit ideality factor register for the remote diode. The ideality factor of the remote diode is programmed in a register to eliminate errors across all temperatures. See section " ...

Page 11

... THERM As described in the SMBus specification, an SMBus slave may inform the SMBus master that it wants to talk by asserting the SMBALERT# signal. One or more as a wired-or bus to a common input. SMSC EMC1002 Table 4.1 Temperature Data Format DEFAULT RANGE BINARY 0000 0000 000 Note 4 ...

Page 12

... ALERT THERM2 SMBus ARA / Response to Temperature Limits Exceeded THERM2 THERM . For the EMC1002-2, the value of this pull-up resistor determines the DD 3. The / pin cannot be masked. Do not exceed 100pf ADDR THERM pin is asserted, it will not de-assert until the temperature drops below the ...

Page 13

... Dual SMBus Sensor with Resistance Error Correction Datasheet 4.7 Standby Mode The EMC1002 can be set to standby mode (low power) by setting a bit in the Configuration Register as described in 4.10, "Configuration Register," on page functions while the SMBus remains enabled. When the EMC1002 is in standby mode, a One-Shot command measurement can be initiated ...

Page 14

... Registers," on page 16 / output is latched and will not be reset until the host ALERT THERM2 Table 4.5 Configuration Register CONFIGURATION REGISTER FUNCTION enabled ALERT disabled ALERT 14 DATASHEET Datasheet for detail on / signal will be asserted. ADDR THERM / signal will not ALERT THERM2 DEFAULT 0 0 SMSC EMC1002 ...

Page 15

... VALUE CONVERSIONS/SECOND 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh to FFh SMSC EMC1002 CONFIGURATION REGISTER FUNCTION ALERT THERM2 ° ° 127 C ° ° 191 C / output. When this bit is set to 0, any out of limit condition ALERT THERM2 ...

Page 16

... SMBus. 4.16 Ideality Factor Register The ideality factor registers are used to program the remote diode ideality factor into the EMC1002 so that this error source can be eliminated. The default ideality factor is 1.008 and has a value of XX010010b or 12h. ...

Page 17

... SMBTE 0 = SMBus timeout disabled 1 = SMBus timeout enabled 6-4 Reserved 3-1 ALERTNUM See 0 Reserved NUMBER OF EVENTS REQUIRED SMSC EMC1002 DIODE IDEALITY VALUE FACTOR XX01 0011 XX10 0011 1.0308 XX01 0100 XX10 0100 1.0321 XX01 0101 XX10 0101 1.0335 XX01 0110 XX10 0110 1 ...

Page 18

... Dual SMBus Sensor with Resistance Error Correction Figure 5.1 Routing the Diode Traces on page .01 WIDE MIN. .01 WIDE MIN. .01 GAP MIN COPPER TRACE COPPER TRACE BOARD MATERIAL COPPER PLANE (TO SHIELD FROM NOISE) Figure 5.1 Routing the Diode Traces 18 DATASHEET Datasheet 18. .01 GAP MIN. GND PLANE SMSC EMC1002 ...

Page 19

... Remote Sensors Connected by Cables When connecting remote diodes with a cable (instead of traces on the PCB) use shielded twisted pair cable. The shield should be attached to ground near the EMC1002, and should be left unconnected at the sensor end. Belden 8451 cable is a good choice for this application. ...

Page 20

... Careful design of the printed circuit board and proper selection of the remote sensing diode will help to maintain the accuracy. Revision 1.4 (12-18-07) 1°C Dual SMBus Sensor with Resistance Error Correction Typical Remote Discrete PNP Transistor Discrete NPN Transistor e.g 2N3906 20 DATASHEET Datasheet Typical Remote e.g. 2N3904 SMSC EMC1002 ...

Page 21

... determined at datum plane H. Maximum mold protrusion or flash is 0.15mm (0.006 inches) per end, and 0.15mm (0.006 inches) per side. 4. Dimension for foot length L measured at the gauge plane 0.25 mm above the seating plane. 5. Details of pin 1 identifier are optional but must be located within the zone indicated. SMSC EMC1002 MAX REMARKS 1.10 Overall Package Height 0 ...

Related keywords