EMC1002-1-ACZT-TR SMSC, EMC1002-1-ACZT-TR Datasheet - Page 13

no-image

EMC1002-1-ACZT-TR

Manufacturer Part Number
EMC1002-1-ACZT-TR
Description
Board Mount Temperature Sensors Dual Zone SMBus Temp Snsr
Manufacturer
SMSC
Datasheet

Specifications of EMC1002-1-ACZT-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1°C Dual SMBus Sensor with Resistance Error Correction
Datasheet
SMSC EMC1002
4.7
4.8
ADDRESS
READ
(HEX)
N/A
FD
FE
FF
00
01
02
03
04
05
06
07
08
10
12
13
14
19
20
21
22
27
29
11
Standby Mode
Register Allocation
The EMC1002 can be set to standby mode (low power) by setting a bit in the Configuration Register
as described in
functions while the SMBus remains enabled. When the EMC1002 is in standby mode, a One-Shot
command measurement can be initiated. The user may also write new values to the limit registers
described in
is outside any of the new limits, the
and the
The registers shown in
Note 4.5
At device power-up, the default values are stored in registers as shown. A power-on-reset is initiated
when power is first applied to the part and the V
undefined registers will return 00h and writes to undefined registers will be ignored.
The EMC1002 uses an interlock mechanism that locks the low byte value when the high byte register
is read. This prevents updates to the low byte register between high byte and low byte reads. This
ADDRESS
WRITE
(HEX)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0A
0C
0D
09
0B
0E
0F
12
13
14
19
20
21
22
27
11
ADDR
Revision number may change. Please obtain the latest version of this document from the
SMSC web site.
4.12, "Limit Registers," on page 16
/
THERM
Internal Temperature Value High Byte
Remote Temperature Value High Byte
Status
Configuration
Conversion Rate
Internal Temperature High Limit
Internal Temperature Low Limit
Remote Temperature High Limit High Byte
Remote Temperature Low Limit High Byte
One-Shot
Remote Temperature Value Low Byte
Scratchpad Byte 1
Scratchpad Byte 2
Remote Temperature High Limit Low Byte
Remote Temperature Low Limit Low Byte
Remote THERM Limit
Internal THERM Limit
THERM Hysteresis
Consecutive ALERT
Internal Temperature Value Low Byte
Product ID
Manufacture ID
Revision Number
4.10, "Configuration Register," on page
Remote Ideality Factor
output will respond as described in
Table 4.3
Table 4.3 EMC1002 Register Map
are accessible through the SMBus.
REGISTER NAME
DATASHEET
ALERT
13
/
THERM2
while in standby. If the previously stored temperature
DD
output will respond as described in
supply exceeds the POR threshold. Reads of
Section
14. This shuts down all internal analog
4.6.
0000 0000
0000 0000
undefined
0000 0000
0000 1000
0101 0101 (85
0000 0000 (0
0101 0101 (85
0000 0000 (0
0000 0000
0000 0000
0000 0000
0000 0000
0000 0000
0101 0101 (85
0101 0101 (85
0000 1010 (10
0000 0001
0001 0010 (1.008)
0000 0000
0000 0010 - EMC1002-1
0000 0011 - EMC1002-2
0101 1101
0000 0001
POWER-ON DEFAULT
Revision 1.4 (12-18-07)
Note 4.5
°
°
°
C)
°
C)
°
°
°
C)
C)
C)
C)
C)
Section 4.5

Related parts for EMC1002-1-ACZT-TR