UWR-12/750-D48A Murata Power Solutions Inc, UWR-12/750-D48A Datasheet - Page 3

DC/DC Converters & Regulators 9W 48V to 12V 750mA

UWR-12/750-D48A

Manufacturer Part Number
UWR-12/750-D48A
Description
DC/DC Converters & Regulators 9W 48V to 12V 750mA
Manufacturer
Murata Power Solutions Inc
Series
UWRr
Datasheet

Specifications of UWR-12/750-D48A

Product
Isolated
Output Power
9 W
Input Voltage Range
18 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
750 mA
Isolation Voltage
1.5 KV
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UWR-12/750-D48A
Manufacturer:
XILINX
Quantity:
850
Part Number:
UWR-12/750-D48A
Quantity:
15
Part Number:
UWR-12/750-D48A-C
Manufacturer:
TI
Quantity:
693
Performance/Functional Specifications
Typical @ T
Input
Output
Environmental
Physical
Input Voltage Range:
Input Current
Input Filter Type
Overvoltage Shutdown:
Reverse-Polarity Protection
V
Temperature Coefficient
Ripple/Noise (20MHz BW)
Line/Load Regulation
Efficiency
Isolation Voltage
Isolation Capacitance
Current Limiting
Overvoltage Protection
Transient Response (50% load step)
Switching Frequency
Flammability
Operating Temperature (Ambient):
Storage Temperature
Dimensions
Shielding
Case Connection:
Case Material
Pin Material
Weight
OUT
Dynamic Characteristics
D5A Models
D12A Models
D24E Models
D48A Models
D48E Models
D5A Models
D12A Models
D24E Models
D48A and D48E Models
Without Derating
With Derating
D5A, D12A and D24E Models
D48A and D48E Models
Except for 3.3V devices which have no protection.
These power converters require a minimum 10% loading to maintain specified regulation.
Operation under no-load conditions will not damage these devices; however they may
not meet all listed specifications.
Application-specific input/output filtering can be recommended and perhaps added
internally upon request for scheduled, quantity orders. Contact DATEL Applications
Engineering for details.
Devices can be screened or modified for higher guaranteed isolation voltages.
Contact DATEL Applications Engineering for details.
Accuracy (50% load)
A
= +25°C under nominal line voltage and full-load conditions, unless noted.
4.7-7.25 Volts (5V nominal)
9-18 Volts (12V nominal)
18-36Volts (24V nominal
18-75 Volts (48V nominal)
36-72 Volts (48V nominal)
See Ordering Guide
Pi
None
20 Volts
40 Volts
76 Volts
Yes (Instantaneous, 6A maximum)
±1%, maximum
±0.02% per °C
See Ordering Guide
See Ordering Guide
See Ordering Guide
1500Vdc, guaranteed
250pF
Auto-recovery
Zener/transorb clamp, magnetic feedback
200μsec max. to ±1.5% of final value
165kHz (±15kHz)
UL94V-0
–40 to +60/65/70°C (Model dependent)
to +100°C (See Derating Curves)
–40 to +105°C
2" x 1" x 0.375" (51 x 25 x 9.5mm)
5-sided
Pin 2 (–V
Pin 1 (+V
Corrosion resistant steel with
non-conductive, epoxy-based, black
enamel finish and plastic baseplate
Gold plate over copper alloy
1.3 ounces (37 grams)
www.murata-ps.com
IN
IN
)
)
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC/DC Converters
Floating Outputs
Since these are isolated DC/DC converters, their outputs are "floating."
Designers will usually use the output Common (pin 5) as the ground/return
of the load circuit. You can, however, use the +Output (pin 3) as ground/
return to effectively reverse the output polarity.
Filtering and Noise Reduction
All A-Series UWR 6-10 Watt DC/DC Converters achieve their rated ripple
and noise specifications without the use of external input/output capaci-
tors. In critical applications, input/output ripple and noise may be further
reduced by installing electrolytic capacitors across the input terminals and/
or low-ESR tantalum or electrolytic capacitors across the output terminals.
The caps should be located as close to the power converters as possible.
Typical values are listed in the tables below. In many applications, using
values greater than those listed will yield better results.
In critical, space-sensitive applications, DATEL may be able to tailor the
internal input/output filtering of these units to meet your specific require-
ments.
Absolute Maximum Ratings
T E C H N I C A L N O T E S
These are stress ratings. Exposure of devices to greater than any of these conditions
may adversely affect long-term reliability. Proper operation under conditions other than
those listed in the Performance/Functional Specifications Table is not implied.
Input Voltage:
Input Reverse-Polarity Protection
Output Overvoltage Protection
Output Current
Storage Temperature
To Reduce Input Ripple
To Reduce Output Ripple
D5A Models
D12A Models
D24E Models
D48A and D48E Models
5/5.2V Outputs
12V Outputs
15V Outputs
D5A Models
D12A and D24E Models
D48A and D48E Models
5/5.2V Outputs
12/15V Outputs
Technical enquiries email: sales@murata-ps.com, tel:
47μF, 10V
20μF, 50V
10μF, 100V
47μF, 10V, Low ESR
22μF, 20V, Low ESR
MDC_UWR6-10W Series.B03 Page 3 of 6
10 Volts
22 Volts
44 Volts
80 Volts
Current must be <6A. Brief
duration only. Fusing recommended.
6.8 Volts, limited duration
15 Volts, limited duration
18 Volts, limited duration
Current limited. Max. current and
short-circuit duration model
dependent.
–40 to +105°C
UWR Series
+1 508 339 3000

Related parts for UWR-12/750-D48A