UWR-12/750-D48A Murata Power Solutions Inc, UWR-12/750-D48A Datasheet - Page 6

DC/DC Converters & Regulators 9W 48V to 12V 750mA

UWR-12/750-D48A

Manufacturer Part Number
UWR-12/750-D48A
Description
DC/DC Converters & Regulators 9W 48V to 12V 750mA
Manufacturer
Murata Power Solutions Inc
Series
UWRr
Datasheet

Specifications of UWR-12/750-D48A

Product
Isolated
Output Power
9 W
Input Voltage Range
18 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
750 mA
Isolation Voltage
1.5 KV
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UWR-12/750-D48A
Manufacturer:
XILINX
Quantity:
850
Part Number:
UWR-12/750-D48A
Quantity:
15
Part Number:
UWR-12/750-D48A-C
Manufacturer:
TI
Quantity:
693
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
HALT Testing
The goal of the accelerated-stress techniques used by DATEL is to force
device maturity, in a short period of time, by exposing devices to excessive
levels of "every stimulus of potential value." We use HALT (Highly Acceler-
ated Life Testing) repeatedly during the design and early manufacturing
phases to detect potential electrical and mechanical design weaknesses
that could result in possible future field failures.
During HALT, prototype and pre-production DC/DC converters are sub-
jected to progressively higher stress levels induced by thermal cycling,
rate of temperature change, vibration, power cycling, product-specific
stresses (such as dc voltage variation) and combined environments. The
stresses are not meant to simulate field environments but to expose any
weaknesses in a product’s electro/mechanical design and/or assembly
processes. The goal of HALT is to make products fail so that device weak-
nesses can be analyzed and strengthened as appropriate. Applied stresses
are continually stepped up until products eventually fail. After corrective
actions and/or design changes, stresses are stepped up again and the cycle
is repeated until the "fundamental limit of the technology" is determined.
DATEL has invested in a Qualmark OVS-1 HALT tester capable of applying
voltage and temperature extremes as well as 6-axis, linear and rotational,
random vibration. A typical HALT profile (shown above) consists of thermal
cycling (–55 to +125°C, 30°C/minute) and simultaneous, gradually increas-
ing, random longitudinal and rotational vibration up to 20G’s with load
cycling and applied-voltage extremes added as desired. Many devices in
DATEL’s new A-Series could not be made to fail prior to reaching either the
limits of the HALT chamber or some previously known physical limit of the
device.
We also use the HALT chamber and its ability to rapidly cool devices to
verify their "cold-start" capabilities.
100
–20
–40
80
60
40
20
0
10
20
30
Typical HALT Profile
40
Test Time (minutes)
50
60
www.murata-ps.com
70
© 2008 Murata Power Solutions, Inc.
80
90
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC/DC Converters
12/04/08
40
20
0
In-Line Process Controls and Screening
A combination of statistical sampling and 100% inspection techniques
keeps our assembly line under constant control. Parameters such as
solder-paste thickness, component placement, cleanliness, etc. are statisti-
cally sampled, charted and fine tuned as necessary. Visual inspections are
performed by trained operators after pick-and-place, soldering and cleaning
operations. Units are 100% electrically tested prior to potting. All devices
are temperature cycled, burned-in, hi-pot tested and final-electrical tested
prior to external visual examination, packing and shipping.
Rapid Response to Problems
DATEL employs an outstanding corrective-action system to immediately
address any detected shortcomings in either products or processes. When-
ever our assembly, quality or engineering personnel spot a product/process
problem, or if a product is returned with a potential defect, we immediately
perform a detailed failure analysis and, if necessary, undertake corrective
actions. Over time, this system has helped refine our assembly operation to
yield one of the lowest product defect rates in the industry.
USA:
Canada:
UK:
France:
Germany:
Japan:
China:
Singapore:
Qualification
For each new product, electrical performance is verified via a comprehen-
sive characterization process and long-term reliability is confirmed via a
rigorous qualification procedure. The qual procedure includes such strenu-
ous tests as thermal shock and 500 hour life. Qual testing is summarized
below.
Qualification Test
HALT
High Temperature Storage
Thermal Shock
Temperature/Humidity
Lead Integrity
Life Test
Marking Permanency
End Point Electrical Tests
* Interim electrical test at 200 hours.
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com
Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel:
Qualification Testing
Method/Comments
DATEL in-house procedure
Max. rated temp., 1,000 hours
10 cycles, –55 to +125°C
+85°C, 85% humidity, 48 hours
DATEL in-house procedure
+70°C, 500 hours*
DATEL in-house procedure
Per product specification
MDC_UWR6-10W Series.B03 Page 6 of 6
UWR Series
+1 508 339 3000

Related parts for UWR-12/750-D48A